Background: The shoulder's ability to participate in sports and activities of daily living depends on its active range of motion. Clinical goniometry is of limited utility in rigorously assessing limitation of motion and the effectiveness of treatment. We sought to determine (1) whether a validated position-sensing tool, the Kinect, can enable the objective clinical measurement of shoulder motion and (2) the degree to which active range of motion correlates with patient self-assessed shoulder function.

Methods: In 10 control subjects, we compared Kinect motion measurements to measurements made on standardized anteroposterior and lateral photographs taken concurrently. In 51 patients, we correlated active motion with the ability to perform the functions of the Simple Shoulder Test (SST).

Results: In controls, Kinect measurements strongly agreed with photographic measurements. In patients, the total SST score was strongly correlated with the range of active abduction. The ability to perform each of the individual SST functions was strongly correlated with active motion. The active motion in well-functioning patient shoulders averaged 155° ± 22° abduction, 159° ± 14° flexion, 76° ± 18° external rotation in abduction, -59° ± 25° internal rotation in abduction, and -3.3 ± 3.7 inches of cross-body adduction, values similar to the control shoulders. Use of the Kinect system was practical in clinical examination rooms, requiring <5 minutes to document the 5 motions in both shoulders.

Discussion: The Kinect provides a clinically practical method for objectively measuring active shoulder motion. Active motion was an important determinant of patient-assessed shoulder function.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2015.07.011DOI Listing

Publication Analysis

Top Keywords

active motion
12
motion
9
shoulder motion
8
active range
8
range motion
8
correlated active
8
ability perform
8
rotation abduction
8
active
6
kinect
5

Similar Publications

Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study.

JMIR Form Res

January 2025

Department of Biomedical Informatics, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.

Background: The iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2's sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work.

Objective: We aimed to assess the iAide2's sleep duration and total sleep time (TST) measurement performance and perform calibration if needed.

View Article and Find Full Text PDF

Background: Adults with spinal deformity (ASD) are known to have spinal malalignment, which can impact their quality of life and their autonomy in daily life activities. Among these tasks, ascending and descending stairs is a common activity of daily life that might be affected.

Research Question: What are the main kinematic alterations in ASD during stair ascent and descent?

Methods: 112 primary ASD patients and 34 controls filled HRQoL questionnaires and underwent biplanar X-from which spino-pelvic radiographic parameters were calculated.

View Article and Find Full Text PDF

Aim The study aimed to detect subtle left ventricular (LV) systolic dysfunction, reflected by abnormal global longitudinal strain (GLS), in patients with stable coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI) and to evaluate any improvement in GLS at 24 hours and six months post-PCI. Methods A total of 94 patients with stable CAD scheduled for elective PCI at our hospital were evaluated using conventional 2D echocardiography and GLS prior to the procedure. Follow-up assessments were conducted at 24 hours and six months post-PCI.

View Article and Find Full Text PDF

Joint degeneration characterized by cartilage deterioration and bone wear is the hallmark of osteoarthritis (OA), a condition that worsens over time. Total knee arthroplasty (TKA) is the most common effective treatment for OA. Conventional therapy training (CTT) is the standard intervention; we are testing whether intensive therapy training (ITT) provides different results when used preoperatively.

View Article and Find Full Text PDF

Osteochondritis dissecans is a rare condition characterized by the deterioration of a small area of bone and cartilage without infection. Its exact cause is unclear, though factors such as abnormal bone development, joint pressure, repetitive injuries, inadequate blood supply, and genetic links have been observed. In this case, a 27-year-old woman experienced chronic right knee pain following a twisting injury, which led to reduced mobility and mild pain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!