Purpose: The aim of this study was to analyze the marginal and internal fit of metalceramic and zirconia-based crowns.

Materials And Methods: Forty standardized steel specimens were prepared to receive posterior crowns and randomly divided into four groups (n = 10): (1) metal-ceramic, (2) NobelProcera Zirconia, (3) Lava Zirconia, and (4) VITA In-Ceram YZ. All crowns were cemented with glass-ionomer agent and sectioned buccolingually. A scanning electron microscope was used for measurements. Kruskal-Wallis and Wilcoxon signed rank test (α = .05) statistical analyses were conducted.

Results: Significant differences (P < .0001) in marginal discrepancies were observed between metal-ceramic and zirconia groups. No differences were found for the axial wall fit (P = .057). Significant differences were shown among the groups in discrepancies at the occlusal cusp (P = .0012) and at the fossa (P = .0062). No differences were observed between surfaces.

Conclusions: All zirconia groups showed better values of marginal discrepancies than the metal-ceramic group. Procera Zirconia showed the lowest gaps.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.4359DOI Listing

Publication Analysis

Top Keywords

marginal internal
8
marginal discrepancies
8
zirconia groups
8
zirconia
5
marginal
4
discrepancies
4
internal discrepancies
4
discrepancies posterior
4
posterior zirconia-based
4
zirconia-based crowns
4

Similar Publications

Dermatofibrosarcoma protuberans (DFSP) is a rare, low to intermediate-grade soft tissue sarcoma that presents significant diagnostic and therapeutic challenges. We report the case of a 40-year-old male patient who presented with a slow-growing, asymptomatic lesion on his forehead that had developed over two years. Clinical examination revealed a firm, non-tender multinodular mass measuring 5 x 3 cm in the supraorbital region.

View Article and Find Full Text PDF

SDSPT2s:SDSPT2 with Selection.

J Chem Theory Comput

January 2025

Qingdao Institute for Theoretical and Computational Sciences and Center for Optics Research and Engineering, Shandong University, Qingdao 266237, China.

As an approximation to SDSCI [static-dynamic-static (SDS) configuration interaction (CI), a minimal MRCI; , , 1481], SDSPT2 [ , , 2696] is a CI-like multireference (MR) second-order perturbation theory (PT2) that treats single and multiple roots in the same manner. This feature permits the use of configuration selection over a large complete active space (CAS) to end up with a much reduced reference space ̃, which is connected only with a small portion (̃) of the full first-order interacting space connected to . The most expensive portion of the reduced interacting ̃ space (which involves three active orbitals) can further be truncated by partially bypassing its generation followed by an integral-based cutoff.

View Article and Find Full Text PDF

Importance: More than 4 million Medicare beneficiaries have enrolled in dual-eligible Special Needs Plans (D-SNPs), and coordination-only D-SNPs are common. Little is known about the impact of coordination-only D-SNPs on Medicaid-covered services and spending, including long-term services and supports, which are financed primarily by Medicaid.

Objective: To evaluate changes in Medicaid fee-for-service (FFS) spending before and after new enrollment in coordination-only D-SNPs vs new enrollment in non-D-SNP Medicare Advantage (MA) plans among community-living beneficiaries enrolled in both Medicare and North Carolina Medicaid.

View Article and Find Full Text PDF

Objectives: This study aimed to assess the vertical misfit at the implant-abutment interface in external and internal connections across various implant brands, comparing original milled titanium abutments with laser-sintered cobalt-chromium (Co-Cr) abutments.

Materials And Methods: A total of 160 implants from four different brands were utilized, with 80 featuring external connections (EC) and 80 internal connections (IC). Original milled titanium abutments (n = 160) and Co-Cr laser-sintered abutments (n = 160) were randomly attached to each connection type, following the manufacturer's recommended torque.

View Article and Find Full Text PDF

Introduction: Long-term care (LTC) residents are frequently transferred to acute care hospitals. Transfer decisions should align with residents' wishes and goals. Decision to transfer to hospital, when not aligned with the resident's wishes, can result in transfers that are harmful to residents, leaving residents in a state of disability that could be considered worse than death.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!