Purpose: Ultrasound-guided interscalene block can be performed using either periplexus or intraplexus needle placement. In this novel study, we histologically examined the needle tip position in relation to the neural tissues with the two techniques. Our objective was to investigate the variable risk of subepineurial needle tip placement resulting from the two ultrasound-guided techniques.

Methods: In an embalmed cadaveric model, periplexus or intraplexus interscalene injections were performed with the side, order, and technique assigned randomly. Under real-time ultrasound guidance, the block needle was placed next to the hyperechoic layer of the plexus (periplexus) or between the hypoechoic nerve roots (intraplexus). Once positioned, 0.1 mL of black acrylic ink was injected. The brachial plexus tissues were then removed and histology sections were prepared and then coded in order to blind two reviewers to group allocation. The area of ink staining was used to determine needle tip location, and the groups were compared for the presence of subepineurial ink.

Results: Twenty-six cadavers had each of the blocks performed on either brachial plexus (i.e., 52 injections). No subepineurial ink deposits were observed in the periplexus group (0%), but subepineurial ink deposition was observed in 3/26 (11.5%) intraplexus injections (odds ratio, 0; 95% confidence interval, 0 to 2.362; P = 0.235). Furthermore, in the intraplexus group, two (of the three) subepineurial ink deposits were observed under the perineurium.

Conclusion: Although our study was somewhat underpowered due to a lower than previously reported rate of subepineurial needle tip positioning, our results suggest that there may be an increased likelihood of subepineurial needle tip position with the intraplexus approach. The periplexus technique resulted in no subepineurial spread of ink, suggesting that this approach may be less likely to result in mechanical trauma to nerves from direct needle injury.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12630-015-0468-yDOI Listing

Publication Analysis

Top Keywords

needle position
12
subepineurial needle
12
subepineurial ink
12
needle
9
ultrasound-guided interscalene
8
interscalene block
8
periplexus intraplexus
8
needle placement
8
subepineurial
8
brachial plexus
8

Similar Publications

Knowledge, Attitudes, and Practices of nurses regarding blood culture collection.

Rev Bras Enferm

January 2025

Universidade Federal de Mato Grosso do Sul. Campo Grande, Mato Grosso do Sul, Brazil.

Objectives: to investigate the knowledge, attitudes, and practices of nurses regarding blood culture collection.

Methods: a cross-sectional study was conducted in five Brazilian public hospitals with 112 nurses. Data were collected using an adapted questionnaire and analyzed through descriptive and inferential statistics.

View Article and Find Full Text PDF

Purpose: To assess the success rate of confirmation of ultrasound-guided intranodal needle positioning by saline injection for dynamic contrast-enhanced magnetic resonance lymphangiography (DCMRL) in pediatric patients.

Material And Methods: Data from children undergoing nodal DCMRL after ultrasound-guided needle positioning into inguinal lymph nodes and validation of the needle position by injection of plain saline solution between 05/2020 and 12/2022 were reviewed. On injection of saline solution, adequate needle position was confirmed by lymph node distension without leakage.

View Article and Find Full Text PDF

Can ACR TI-RADS predict the malignant risk of medullary thyroid cancer?

J Clin Transl Endocrinol

March 2025

Department of Ultrasound, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, PR China.

Objectives: This study aimed to evaluate the diagnostic performance for medullary thyroid cancer (MTC) based on the 2017 Thyroid Imaging Reporting and Data System by the American College of Radiology (ACR TI-RADS) guideline, and the ability to recommend fine needle aspiration (FNA) for MTC.

Methods: Fifty-six MTCs were included, and 168 benign thyroid nodules (BTNs) and 168 papillary thyroid nodules (PTCs) were matched according to age. Ultrasound (US) features were reviewed according to ACR TI-RADS.

View Article and Find Full Text PDF

Background: It is very well known that the supraclavicular nerve (SCN) which occupies the inferior part of the superficial cervical plexus basically originates from the ventral rami of C2-C4, then travels caudally into the investing layer of the deep cervical fascia (IL-DCF) alternatively termed the "prevertebral fascia."

Methods: This cadaveric study (a total of 6 soft-embalmed cadavers and bilateral dissections, i.e.

View Article and Find Full Text PDF

Purpose: High dose rate (HDR) prostate brachytherapy (BT) procedure requires image-guided needle insertion. Given that general anesthesia is often employed during the procedure, minimizing overall planning time is crucial. In this study, we explore the clinical feasibility and time-saving potential of artificial intelligence (AI)-driven auto-reconstruction of transperineal needles in the context of US-guided prostate BT planning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!