A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation. | LitMetric

Our objective was to clarify whether thrombogenic problems with stent struts are resolved at 3 months after 2nd-generation drug-eluting stent implantation. Twenty-one patients with stable angina pectoris having 28 (22 zotarolimus-eluting, 6 everolimus-eluting) stents with optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) were evaluated. Stent strut coverage and malapposition were evaluated by OCT immediately after PCI and at 3-month follow-up. Acute strut malapposition was observed in 26 out of 28 analyzed stents (92.9 %). At 3-month follow-up, 7 (26.9 %) of those 26 stents with strut malapposition were completely resolved, and the mean percentages of uncovered struts and malapposed struts were 8.3 and 2.0 % when analyzed by each individual stent. When analyzing a total of 30,060 struts, 807 struts (2.7 %) demonstrated acute strut malapposition. Among these, 219 struts (27.1 %) demonstrated persistent strut malapposition. On the basis of receiver-operating characteristic curve analysis, a strut-to-vessel (S-V) distance ≤160 µm on post-stenting OCT images was the corresponding cutoff point for resolved malapposed struts (sensitivity 78.1 %, specificity 62.8 %, area under the curve 0.758). The S-V distance of persistent malapposed struts on post-stenting OCT images was longer than that of resolved malapposed struts (235 ± 112 vs. 176 ± 93 µm, p < 0.01). At 3 months after PCI, the prevalence rates of uncovered and malapposed struts were relatively low in 2nd-generation drug-eluting stent. Our results suggest that OCT-guide PCI with an S-V distance ≤160 µm may be recommended especially in patients with planed short-term DAPT.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-015-0737-2DOI Listing

Publication Analysis

Top Keywords

strut malapposition
20
malapposed struts
16
struts
9
optical coherence
8
coherence tomography
8
stent strut
8
2nd-generation drug-eluting
8
drug-eluting stent
8
stent implantation
8
3-month follow-up
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!