A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasonography of the Optic Nerve Sheath Diameter for Diagnosis and Monitoring of Acute Mountain Sickness: A Systematic Review. | LitMetric

Aims: Despite extensive research on acute mountain sickness (AMS), the underlying pathophysiology remains unclear. Ultrasonography studies have shown that optic nerve sheath diameter (ONSD) correlates with intracranial pressure (ICP) in critical care patients, and recent studies report elevated ONSD values at high altitude. The aim of this review was to elucidate whether 1. measurement of ONSD could shed light on the pathophysiology of AMS, and 2. ultrasonography of the ONSD could support the diagnosis of AMS.

Methods: Systematic search of MEDLINE (through Pubmed; from 1966 to 14 October 2014), Cochrane Central Register of Controlled Trials (CENTRAL), and EMBASE databases.

Results: Six studies with 436 subjects (139 women, 297 men; 406 mostly Caucasian; 30 Nepalese) were included. A marked variability in ONSD was found across studies both at baseline and at high altitude.

Conclusion: The variability in ONSD across the included studies and within each study limit the utility of ONSD measurement in the diagnosis of AMS. ONSD measurements might be useful from a population perspective, but the accuracy of optic nerve ultrasonography for single subjects and single point-in-time assessment for diagnosing AMS is questionable due to high individual variability in ONSD.

Download full-text PDF

Source
http://dx.doi.org/10.1089/ham.2014.1127DOI Listing

Publication Analysis

Top Keywords

optic nerve
12
variability onsd
12
onsd
9
nerve sheath
8
sheath diameter
8
acute mountain
8
mountain sickness
8
studies
5
ultrasonography
4
ultrasonography optic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!