Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Distinguishing dengue virus infection from other febrile thrombocytopenic illnesses such as leptospirosis or enteric fever is important but difficult, due to the unavailability of reliable diagnostic tests. Sysmex XE-5000 hematology analyzers use fluorescence flow cytometry to quantitate new parameters including cells in the atypical lymphocyte area (AL), high-fluorescent lymphocyte counts (HFLC), immature granulocytes (IG), and immature platelets (IPF). This study aimed to investigate whether these parameters can help to discriminate between the diseases.
Material And Methods: We compared hematocytometry performed by a Sysmex XE-5000 analyzer in Indonesian adults with dengue (n = 93), leptospirosis (n = 11), and enteric fever (n = 6) infection, and in healthy controls (n = 28).
Results: Receiver operating characteristic curves comparing dengue and leptospirosis showed that dengue was characterized by increased %AL (AUC 0.87; 95% CI 0.70-1.03), %HFLC (AUC 0.89; 95% CI 0.78-0.99), and %IPF (AUC 0.81; 95% CI 0.65-0.97), while patients with leptospirosis had increased %IG (AUC 0.86; 95% CI 0.71-1.02). Low %AL, %HFLC, and %IG supported a diagnosis of enteric fever.
Conclusions: The detection of AL, HFLC, IG, and IPF by Sysmex XE-5000 hematology analyzers can help to differentiate between common causes of febrile illnesses with thrombocytopenia in dengue endemic areas. We recommend further investigating the discriminatory value of these parameters in clinical practice.