Introduction: Isolation of pulmonary veins (PVs) and the posterior left atrium (LA) can be safely performed by radiofrequency hot balloon (RHB)-based box isolation. However, data on long-term effects for the treatment of atrial fibrillation (AF) by the use of this method remain limited.

Methods And Results: We treated 238 patients with paroxysmal AF (194 male; age. 62.6 ± 9.4 years) by RHB ablation. During 6.2-year (75 months) follow-up, 154 (64.7%) patients were free from atrial tachyarrhythmias (ATAs) without antiarrhythmic-drugs (AADs). We performed re-ablation in 69 of 84 patients with ATA recurrence (average 1.3 ± 0.6; median 1, total 91 procedures) using a 3D-mapping system and a conventional catheter. The sites of reconnection were observed at the PV in 61 of 69 (88.4%) patients and at the posterior LA in 58 of 69 (84.1%) patients. Finally, during mean follow-up of 4.6 ± 1.6 years, no-ATA episodes were detected in 201 (84.5%) patients without AADs. Independent predictors of ATA recurrence following a single procedure were heart failure with preserved ejection fraction (HR: 2.67, 95%CI: 1.40-5.10, P = 0.003) and low estimated glomerular filtration rate (HR: 1.81, 95%CI: 1.11-2.93, P = 0.03; cut-off of 62.0 mL/min/1.73 m(2)). During the follow-up period, there were 4 (1.7%) patients with PV stenosis (>70% reduction in PV diameter); however, none of these cases required intervention. Phrenic nerve palsy was detected in 8 patients (3.4%), but resolved during 3 months in all cases.

Conclusion: RHB ablation can be effective during a long-term follow-up for patients with paroxysmal AF. Safety outcomes were within an acceptable range.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.12820DOI Listing

Publication Analysis

Top Keywords

patients paroxysmal
12
patients
10
radiofrequency hot
8
hot balloon
8
atrial fibrillation
8
rhb ablation
8
ata recurrence
8
long-term radiofrequency
4
balloon ablation
4
ablation patients
4

Similar Publications

Introduction: The efficacy and safety of statins for secondary prevention in patients who have experienced a cardioembolic stroke are not well-defined. However, previous observational data reported hyperlipidemia as a risk factor for both ischemic and bleeding complications in patients with AF and previous stroke. Based on these premises, we conducted a sub-analysis of the RAF and RAF-NOAC studies to evaluate the efficacy and safety of statins in secondary prevention in patients with acute ischemic stroke and AF.

View Article and Find Full Text PDF

Comparison of Catheter Ablation in Patients with Paroxysmal Non-valvular Atrial Fibrillation and Heart Failure with Preserved Ejection Fraction.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

The efficacy of radiofrequency ablation (RFA) in patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) has been established, but the efficacy and safety of cryoballoon ablation (CBA) and pulsed field ablation (PFA) remain unclear. This retrospective cohort study included 223 patients with paroxysmal non-valvular AF and HFpEF who underwent their first AF ablation between January 2017 and December 2021 and were divided into RFA (n = 77), CBA (n = 127), and PFA (n = 19) groups. After a mean follow-up of 11.

View Article and Find Full Text PDF

Objective: To investigate the effect of hyperbaric oxygen (HBO) on paroxysmal sympathetic hyperexcitation (PSH) after brain injury.

Methods: A multicenter retrospective study was conducted. Fifty-six patients with PSH who received HBO treatment from four hospitals in Henan Province from January 2021 to September 2023 were selected as the HBO group, and 36 patients with PSH who did not receive HBO treatment from Zhengzhou People's Hospital from May 2018 to December 2020 were selected as the control group.

View Article and Find Full Text PDF

Electrical cardioversion presents one of the treatment options for atrial fibrillation (AF). However, the early recurrence rate is high, reaching ~40% three months after the procedure. Features based on vectorcardiographic signals were explored to find association with early recurrence of AF.

View Article and Find Full Text PDF

Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study.

J Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK; Department of Cardiovascular Sciences, Clinical Science Wing, University of Leicester, Glenfield Hospital, Leicester, UK; National Institute for Health Research Leicester Research Biomedical Centre, Leicester, UK.

Background: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods.

Methods: This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!