Background: The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique.

Methods: Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (P f ) and tibial coronal plane (P t ), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (P f and P t ) during normal gait.

Results: With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°.

Conclusions: Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4553277PMC
http://dx.doi.org/10.4055/cios.2015.7.3.303DOI Listing

Publication Analysis

Top Keywords

screw-home movement
20
knee joint
16
movement tibiofemoral
8
tibiofemoral joint
8
joint normal
8
normal gait
8
fifteen young
8
knee joints
8
virtual planes
8
coronal plane
8

Similar Publications

Purpose: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed-bearing, posterior-stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert.

Methods: A consecutive series of patients (16 TKAs from each treatment group) participating in a randomised controlled trial comparing TKA migration was included. The exclusion criterion was the use of walking aids.

View Article and Find Full Text PDF

Introduction The knee joint, an extraordinary feat of biomechanics, is prone to injuries, with the anterior cruciate ligament (ACL) often being a common victim. The intricate coordination of joint movements relies heavily on the ACL's screw-home mechanism, a crucial element for synchronizing knee movement with neighboring joints. Despite its indispensable role, the ACL is susceptible to injury, necessitating surgical intervention.

View Article and Find Full Text PDF

Background: Bi-cruciate retaining total knee arthroplasty with an asymmetrical design may improve knee function and clinical outcomes. This study aimed to compare the kinematics, anteroposterior laxity, and in situ forces of the anterior and posterior cruciate ligaments of knees subjected to this treatment with those of healthy knees.

Methods: Seven fresh-frozen cadaveric knees were tested using a robotic/universal force-moment sensor system.

View Article and Find Full Text PDF

Aims: The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA).

Methods: A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively.

View Article and Find Full Text PDF

Objectives: This study uses a practical positional MRI protocol to evaluate tibiofemoral translation and rotation in normal and injured knees.

Methods: Following ethics approval, positional knee MRI of both knees was performed at 35° flexion, extension, and hyperextension in 34 normal subjects (mean age 31.1 ± 10 years) and 51 knee injury patients (mean age 36.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!