Purpose: This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles.
Methods: A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper.
Results: Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system.
Conclusions: The gate Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4545103 | PMC |
http://dx.doi.org/10.1118/1.4928484 | DOI Listing |
Bioeng Transl Med
January 2025
Research Institute of Transplant Medicine, Tianjin First Central Hospital, School of Medicine, Nankai University Tianjin China.
Pump is a vital component for expelling the perfusate in small animal isolated organ normothermic machine perfusion (NMP) systems whose flexible structure and rhythmic contraction play a crucial role in maintaining perfusion system homeostasis. However, the continuous extrusion forming with the rigid stationary shaft of the peristaltic pumps can damage cells, leading to metabolic disorders and eventual dysfunction of transplanted organs. Here, we developed a novel biomimetic blood-gas system (BBGs) for preventing cell damage.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Pediatric Cardiovascular Surgery, Pediatric Heart Center, Department of Surgery, University Children's Hospital Zurich, 8008 Zurich, Switzerland.
Pediatric patients supported by extracorporeal ventricular assist devices traditionally require long-term stationary inpatient settings. Limited mobility and permanent hospitalization significantly reduce their quality of life. Berlin Heart address this with their novel mobile driving unit, EXCOR Active.
View Article and Find Full Text PDFPediatr Radiol
December 2024
Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, USA.
Background: Evaluation of cardiothoracic pathologies is a common indication for computed tomography (CT) in infants. However, CT is fraught with challenges specific to the patient population, such as increased sensitivity to radiation and inability to remain stationary during imaging.
Objective: This study investigates potential advantages of a high-pitch helical CT protocol for infants with cardiothoracic pathologies.
Am J Hypertens
November 2024
Cardiovascular Aging Research Laboratory, Department of Kinesiology and Health Education, The University of Texas at Austin, Austin, TX.
Background: During laboratory testing, participants rest quietly in a supine posture with little movement. However, it is rather common for participants to display various behaviors. The extent to which these common encounters influence cardiovascular measures is unknown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!