Anterior Segment Optical Coherence Tomography Assessment After Laser Capsulotomy in Pseudophakic Eyes With Pseudoexfoliation.

Eye Contact Lens

Department of Ophthalmology (M.E., S.K.E., G.G., M.O., C.A., C.A.A.), Istanbul Medipol University School of Medicine, Istanbul, Turkey; and Department of Ophthalmology (H.B.), Medeniyet University School of Medicine, Istanbul, Turkey.

Published: September 2016

Purpose: To assess changes in anterior-chamber depth (ACD) and angle width after neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy pseudophakia in eyes with pseudoexfoliation (PEX).

Methods: This prospective and interventional case series study included 25 pseudophakic eyes of 25 patients with PEX and 26 pseudophakic eyes of 26 patients without PEX scheduled for Nd:YAG laser capsulotomy in a single institution. Anterior-chamber depth and angle width were measured with anterior segment optical coherence tomography before and three days after Nd:YAG laser capsulotomy. Preoperative and postoperative measurements of ACD and angle width included the angle opening distance (AOD), measured as the perpendicular distance from the trabecular meshwork at 500 and 750 mm anterior to the scleral spur to the anterior iris surface (AOD500 and AOD750, respectively) and anterior-chamber angle (ACA) in the nasal and temporal quadrants. Main outcome measures were the changes in ACD and angle width parameters.

Results: The mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.67±0.12 mm, 0.63±0.05 mm and 0.65±0.05 mm, 0.67±0.06 mm and 0.77±0.04 mm, 35.25±1.69° and 35.37±1.68° in eyes with PEX and 3.73±0.11 mm, 0.6±0.05 mm and 0.63±0.05 mm, 0.66±0.06 mm and 0.74±0.06 mm, 34.24±1.6° and 34.6±1.47° in control eyes, respectively (P>0.05 for all). After Nd:YAG laser capsulotomy, mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.76±0.09 mm, 0.73±0.05 mm and 0.76±0.05 mm, 0.75±0.06 mm and 0.87±0.04 mm, 36.82±1.46° and 35.06±1.52° in eyes with PEX and 3.77±0.1 mm, 0.68±0.06 mm and 0.72±0.06 mm, 0.72±0.05 mm and 0.84±0.06 mm, 34.95±1.4° and 35.79±1.36° in control eyes, respectively (P=0.811, P=0.019, P=0.021, P=0.109, P=0.126, P=0.001, and P=0.01, respectively).

Conclusions: The depth and width of the anterior chamber in eyes with PEX and in control eyes increased significantly after Nd:YAG laser capsulotomy. The change in the width of the anterior chamber in eyes PEX was statistically significant comparing control eyes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0000000000000185DOI Listing

Publication Analysis

Top Keywords

laser capsulotomy
24
ndyag laser
20
angle width
16
eyes pex
16
control eyes
16
eyes
12
pseudophakic eyes
12
acd angle
12
aod500 aod750
12
aca nasal
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!