Background: Pleiotropic effects of statins decrease intrahepatic resistance and portal hypertension.

Aim: We evaluated the effects of simvastatin on hepatic venous pressure gradient (HVPG) and azygos vein blood flow in cirrhotic patients.

Methods: A 3-month prospective, randomized, triple-blind trial with simvastatin (40 mg/day) vs. placebo was conducted in patients with cirrhotic portal hypertension. HVPG and azygos blood flow, measured by colour Doppler endoscopic ultrasound, were assessed before and after treatment. The primary endpoint was a decrease in the HVPG of at least 20% from baseline or to ≤12 mmHg after the treatment.

Results: 34 patients were prospectively enrolled, and 24 completed the protocol. In the simvastatin group 6/11 patients (55%) presented a clinically relevant decrease in the HVPG; no decrease was observed in the placebo group (p=0.036). Patients with medium/large oesophageal varices and previous variceal bleeding had a higher response rate to simvastatin. HVPG and azygos blood flow values were not correlated. No significant adverse events occurred.

Conclusion: Simvastatin lowers portal pressure and may even improve liver function. The haemodynamic effect appears to be more evident in patients with severe portal hypertension.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dld.2015.07.156DOI Listing

Publication Analysis

Top Keywords

portal hypertension
12
hvpg azygos
12
blood flow
12
severe portal
8
azygos blood
8
decrease hvpg
8
simvastatin
6
portal
5
hvpg
5
patients
5

Similar Publications

Unlabelled: Sinusoidal obstruction syndrome (SOS) is a distinctive and potentially fatal form of hepatic injury that mainly occurs after hematopoietic-stem cell transplantation but also due to many other conditions including drug or toxin exposure. Recently, immune checkpoint inhibitors (ICIs) have revolutionised the treatment of many solid organ malignancies. Furthermore, as their use has become more widespread, rare toxicities have emerged.

View Article and Find Full Text PDF

Portal vein recanalization transjugular intrahepatic portosystemic shunt (PVR-TIPS) is a safe and effective procedure for decompression of portal hypertension (PH). In this short case series, 2 women with chronic noncirrhotic portal vein thrombosis were treated with PVR-TIPS. Both patients hoped to conceive.

View Article and Find Full Text PDF

Purpose: This study assesses the efficacy and safety of Portal Vein Recanalization with Intrahepatic Portosystemic Shunt (PVR-TIPS) in non-cirrhotic patients with chronic portal vein occlusion (CPVO), cavernomatous transformation, and symptomatic portal hypertension (PH) and/or portal vein thrombotic progression.

Material And Methods: Medical records of 21 non-cirrhotic patients with CPVO and portal cavernoma undergoing PVR-TIPS were analyzed. Hemodynamic (intraprocedural reduction in portosystemic pressure gradient), clinical (data on gastrointestinal bleeding, abdominal pain, ascites, and presence of esophageal varices from imaging exams) and technical success (PVR-TIPS) assessed efficacy.

View Article and Find Full Text PDF

Numerical assessment of portal pressure gradient (PPG) based on clinically measured hepatic venous pressure gradient (HVPG) for liver cirrhosis patients.

J Biomech

January 2025

Department of Gastroenterology and Hepatology and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, PR China; Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan 610041, PR China. Electronic address:

Portal hypertension (PH) is the initial and main consequence of liver cirrhosis. Hepatic venous pressure gradient (HVPG) measurement has been widely used to estimate portal pressure gradient (PPG) and detect portal hypertension. However, some clinical studies have found poor correlation between HVPG and PPG, which may lead to the misdiagnosis of portal hypertension.

View Article and Find Full Text PDF

The use of ultrasound contrast agents (UCAs) for estimating portal pressure has recently gained attention due to its clinical promise, yet variability in acoustic amplitude poses challenges. UCAs contain microbubbles (1-10 µm in diameter), and understanding their acoustic response is essential to address this variability. However, systematic exploration of factors influencing microbubble behavior remains limited in current literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!