Insight into the Assembly of Viruses with Vertical Single β-barrel Major Capsid Proteins.

Structure

Structural Biology Unit, CIC bioGUNE, CIBERehd, Bizkaia Technology Park, 48160 Derio, Spain; IKERBASQUE, Basque Foundation for Science, 48013 Bilbao, Spain. Electronic address:

Published: October 2015

Archaeal viruses constitute the least explored niche within the virosphere. Structure-based approaches have revealed close relationships between viruses infecting organisms from different domains of life. Here, using biochemical and cryo-electron microscopy techniques, we solved the structure of euryarchaeal, halophilic, internal membrane-containing Haloarcula hispanica icosahedral virus 2 (HHIV-2). We show that the density of the two major capsid proteins (MCPs) recapitulates vertical single β-barrel proteins and that disulfide bridges stabilize the capsid. Below, ordered density is visible close to the membrane and at the five-fold vertices underneath the host-interacting vertex complex underpinning membrane-protein interactions. The HHIV-2 structure exemplifies the division of conserved architectural elements of a virion, such as the capsid, from those that evolve rapidly due to selective environmental pressure such as host-recognizing structures. We propose that in viruses with two vertical single β-barrel MCPs the vesicle is indispensable, and membrane-protein interactions serve as protein-railings for guiding the assembly.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.str.2015.07.015DOI Listing

Publication Analysis

Top Keywords

vertical single
12
single β-barrel
12
viruses vertical
8
major capsid
8
capsid proteins
8
membrane-protein interactions
8
insight assembly
4
viruses
4
assembly viruses
4
β-barrel major
4

Similar Publications

Total anomalous pulmonary venous return (TAPVR) is a high risk and rare cardiac malformation with a low prenatal detection rate and predicting obstruction in these cases is difficult. We sought to investigate fetal echocardiographic parameters associated with postnatal pulmonary venous obstruction (PPVO). We performed a retrospective review of 26 patients with TAPVR who had a fetal echocardiogram from 2010 to 2021.

View Article and Find Full Text PDF

Theoretical modeling and modal analysis of multi-element coupled transducers.

J Acoust Soc Am

January 2025

National Key Laboratory of Underwater Acoustic Technology, Harbin Engineering University, Harbin 150001, China.

Low-frequency transducers are considerably smaller than the wavelength. When multiple low-frequency transducers are closely packed, they couple with the surrounding water and form a transducer-water-transducer coupling structure called multi-element coupled transducers (MCT). This study presents a theoretical model of the MCT based on radiation and mutual radiation theory and analyzes it under multiple resonance frequencies and vibration modes.

View Article and Find Full Text PDF

Objectives: To study the clinical effect of the L-shape technique combined with concentrated growth factor on the horizontal bone defects of maxillary anterior teeth.

Methods: Twenty-five implants from 25 patients who underwent single maxillary anterior tooth implantation with simultaneous bone grafting were selected as the study subjects. Based on the bone grafting techniques, the patients were divided into a test group (L-shaped technique with guided bone regeneration combined with concentrated growth factor, 11 cases) and a control group (traditional guided bone regeneration combined with concentrated growth factor, 14 cases).

View Article and Find Full Text PDF

Purpose: Speed is a crucial physical characteristic where each lower-limb ankle plantar-flexor (PF) muscle needs to generate significant force; however, there is limited evidence about the relationship between single-limb isometric, and reactive strength forms, and linear sprint. The aim of this study was to determine the impact of the maximal unilateral isometric strength of the ankle PF muscle and reactive strength on sprint acceleration performance.

Material And Methods: Thirty-two male floorball players (mean [SD] age 20.

View Article and Find Full Text PDF

Objective: This study aimed at investigating implant survival rate and marginal bone loss (MBL) around extra-short implants. The impact of the loading protocol and of the use of an intermediate abutment was also evaluated, to explore possible differences in terms of the outcome measures.

Materials And Methods: Patients with single or multiple mandibular or maxillary posterior edentulism rehabilitated using extra-short 5-6 mm long implants were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!