Background/aims: To report the short-term safety profile and clinical outcomes of scleral fixation of intraocular lenses (IOLs) using Gore-Tex suture.

Methods: Retrospective, interventional case series. 85 eyes of 84 patients undergoing ab externo scleral fixation of a Bausch and Lomb Akreos AO60 or Alcon CZ70BD IOL using Gore-Tex suture. Primary outcome measures were change in visual acuity and occurrence of intraoperative and postoperative complications with minimum follow-up of 90 days.

Results: 85 eyes of 84 patients were identified. Mean logarithm of the minimum angle of resolution visual acuity improved from 1.43±0.72 (20/538 Snellen equivalent) preoperatively to 0.64±0.61 (20/87 Snellen equivalent) postoperatively (p<0.001). Mean follow-up was 325 days (median 264 days, range 90-996 days). There were no intraoperative complications noted. Postoperative complications included hypotony in eight patients (9.4%), ocular hypertension in six eyes (7%), vitreous haemorrhage in six eyes (7%), hyphema in two eyes (2%), serous choroidal detachment in two eyes (2%), cystoid macular oedema in two eyes (2%) and corneal oedema in one eye (1%). There were no cases of postoperative endophthalmitis, suture erosion/breakage, retinal detachment, suprachoroidal haemorrhage, uveitis-glaucoma-hyphema syndrome or persistent postoperative inflammation in the follow-up period.

Conclusions: Ab externo scleral fixation of IOLs with Gore-Tex suture was well tolerated in all cases. No suture-related complications were encountered. This procedure led to improvement in visual acuity and was not associated with significant intraoperative or postoperative complications.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2015-306839DOI Listing

Publication Analysis

Top Keywords

scleral fixation
12
fixation intraocular
8
intraocular lenses
8
gore-tex suture
8
clinical outcomes
8
safety profile
8
eyes patients
8
visual acuity
8
snellen equivalent
8
lenses gore-tex
4

Similar Publications

This retrospective observational multicentre cohort study compared the rate of postoperative cystoid macular oedema (CME) between two intraocular lens (IOL) scleral fixation (SFIOL) techniques: a flanged IOL fixation technique (Yamane technique) and a suture IOL transscleral fixation technique (conventional technique). The study included 207 eyes with postoperative CME that had undergone SFIOL and were observed for > 12 weeks between January 2019 and January 2021. The primary endpoint was a comparison of the rate of postoperative CME at 3 months between groups.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the long-term outcomes of scleral fixation of aniridic black diaphragm intraocular lenses (BDIOL) in 38 eyes affected by aniridia and aphakia due to trauma or congenital conditions.
  • After an average follow-up of 28 months, there was a significant improvement in visual acuity, and patients reported reduced glare and photophobia, though some experienced complications like elevated intraocular pressure and corneal decompensation.
  • The findings suggest that scleral fixation of BDIOL is an effective solution for patients lacking capsular support, providing good vision quality with a low rate of complications, regardless of prior surgical history.
View Article and Find Full Text PDF

Comparing dislocation force between a flanged haptics IOL and a harpoon haptics IOL.

Sci Rep

December 2024

Vienna Institute for Research in Ocular Surgery (VIROS), A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.

To compare two different secondary IOL fixation techniques, either flanged or hooked, regarding the least required force to dislocate the haptic in human corneoscleral donor tissue (CST). Experimental laboratory investigation. The least required dislocation force (LRDF) of two different fixation techniques, namely the flanged haptics (FH, as described by Yamane) and the harpoon haptic technique (HH, as described by Carlevale) were investigated using 20 three-piece IOLs (KOWA PU6AS) and 20 single-piece IOLs (SOLEKO CARLEVALE) fixated to human scleral tissue.

View Article and Find Full Text PDF

Purpose: To evaluate the outcomes of scleral-fixated intraocular lenses (IOLs) implanted using either Yamane technique or Gore-Tex suture fixation, in comparison to intracapsular lens fixation, and to assess the efficacy of various lens formulas in achieving predicted refractive targets.

Patients And Methods: This study included 45 eyes from 44 patients with scleral-fixated IOLs, comprising 37 Yamane eyes and 8 Gore-Tex eyes. Preoperative refractive predictions from various formulae were compared with final postoperative refraction.

View Article and Find Full Text PDF

Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!