The value and extent in which balloon dilatation increases the valve area in severe bioprosthesis stenosis has not been defined. In-vitro double balloon dilatation, using 15 to 20 mm diameter Meditech balloon catheters, simultaneously inflated to 5 atmospheres, was attempted in 10 intact, stenosed, surgically excised bioprosthetic valves, 7 mitral and 3 aortic, size 21 to 35 mm. Radiological studies and calculation of the valve area, using a conical sizer, were performed both before and after balloon dilatation. After balloon dilatation the valve area was increased from 1.1 +/- 0.4 to 2.0 +/- 0.5 cm2 (p less than 0.001). The valve area increase was due to improved leaflet mobility in all cases. Leaflet calcium fractures were noted in 9 valves, 5 exhibited leaflet tears and the valve annulus was distorted in 3. A control group of balloon dilatation in 10 unused bioprostheses of the same sizes showed no leaflet tears. The mechanism of valve area increase, (80%), of stenotic bioprostheses by balloon dilatation, is improvement in leaflet mobility, partially secondary to leaflet calcium fractures and tears. Despite the marked increase in the bioprosthesis valve area the induction of leaflet tears will limit the clinical use of this technique for the dilatation of stenosed bioprosthetic valve.

Download full-text PDF

Source

Publication Analysis

Top Keywords

valve area
28
balloon dilatation
28
area increase
12
leaflet tears
12
balloon
8
dilatation
8
dilatation stenosed
8
valve
8
leaflet mobility
8
leaflet calcium
8

Similar Publications

Blood coagulation monitoring of patients with mechanical heart valve visiting Imam.

J Cardiothorac Surg

January 2025

Cardiovascular Research Center, Health Policy and Promotion Institute, Imam-Ali Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran.

Background: The lacking proper regulation of International Normalized Ratio (INR) as the main problem in patients with mechanical valve replacement surgery poses the risk of thrombosis and embolism on the one hand and the risk of bleeding on the other. For this reason, the correct monitoring of INR via the Time in Therapeutic Range (TTR) is needed. The present study aimed to explore the blood coagulation monitoring of patients with mechanical heart valve in Imam Ali Hospital of Kermanshah in 2021.

View Article and Find Full Text PDF

Risk factors for long-term severe tricuspid regurgitation following mitral valve replacement: a retrospective study.

BMC Cardiovasc Disord

January 2025

Department of Cardiology, Xuzhou Central Hospital, No.199 Jiefang South Road, Quanshan District, Xuzhou, 221009, People's Republic of China.

Background: The aim of this study is to identify factors associated with the development of long-term severe tricuspid regurgitation (TR) following mitral valve replacement (MVR).

Methods: A retrospective analysis was conducted involving 308 patients who underwent single-valve MVR at Xuzhou Central Hospital between April 2017 and December 2022. Preoperative color Doppler ultrasound indicated that all patients had either no or mild to moderate tricuspid regurgitation.

View Article and Find Full Text PDF

Objective: Ventricular shunt insertion is a common procedure in pediatric neurosurgical practice. In many areas of medicine there is a push toward rationalization of healthcare resources and a reduction in low-value tests or procedures. The intraoperative sampling of CSF at the time of shunt insertion is one traditional aspect of care that has not been rigorously evaluated.

View Article and Find Full Text PDF

Right Atrial Cardiac Hemangioma: A Multidisciplinary Pathway From Symptoms to Surgery.

JACC Case Rep

December 2024

Groupement de Coopération Sanitaire-Groupement des Hôpitaux de l'Institut Catholique de Lille/Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, DATACARD (Données Arythmie Technologie et imAgerie CARDio-vasculaire), ETHICS (Experience, technology & human interactions, care & society) EA 7446, Lille Catholic University, Lille, France.

We present a case of a 76-year-old man with de novo right heart failure. Echocardiography initially detected a mass near to the posterior area of the right atrium. Despite a comprehensive multimodality imaging assessment, the exact location of the mass remained unclear.

View Article and Find Full Text PDF

Objective: To identify the risk factors associated with moderate to severe perivalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) and to construct a prediction model for this risk.

Methods: A retrospective analysis was conducted on 128 patients with severe aortic stenosis who had received TAVR in The Second Hospital of Hebei Medical University from January 2019 to January 2024. The length of the aortic regurgitation bundle and annular circumference ratio were measured by transesophageal echocardiography immediately after the valve implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!