Model-Updated Image-Guided Neurosurgery: Preliminary Analysis Using Intraoperative MR.

Med Image Comput Comput Assist Interv

University Hospital, Department of Neurological Surgery, Heidelberg School of Medicine, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany.

Published: October 2000

In this paper, initial clinical data from an intraoperative MR system are compared to calculations made by a three-dimensional finite element model of brain deformation. The preoperative and intraoperative MR data was collected on a patient undergoing a resection of an astrocytoma, grade 3 with non-enhancing and enhancing regions. The image volumes were co-registered and cortical displacements as well as subsurface structure movements were measured retrospectively. These data were then compared to model predictions undergoing intraoperative conditions of gravity and simulated tumor decompression. Computed results demonstrate that gravity and decompression effects account for approximately 40% and 30%, respectively, totaling a 70% recovery of shifting structures with the model. The results also suggest that a non-uniform decompressive stress distribution may be present during tumor resection. Based on this preliminary experience, model predictions constrained by intraoperative surface data appear to be a promising avenue for correcting brain shift during surgery. However, additional clinical cases where volumetric intraoperative MR data is available are needed to improve the understanding of tissue mechanics during resection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548986PMC
http://dx.doi.org/10.1007/978-3-540-40899-4_12DOI Listing

Publication Analysis

Top Keywords

intraoperative data
8
model predictions
8
intraoperative
6
data
5
model-updated image-guided
4
image-guided neurosurgery
4
neurosurgery preliminary
4
preliminary analysis
4
analysis intraoperative
4
intraoperative paper
4

Similar Publications

This study assesses the effect of carotid sinus blockade applied with a local anesthetic on hemodynamic parameters during carotid endarterectomy (CEA) operations performed under general anesthesia. The medical records of patients who underwent CEA under general anesthesia between January 2020 and December 2022, were retrospectively reviewed. It was recorded whether the patients received carotid sinus block with 2 mL of 2% prilocaine.

View Article and Find Full Text PDF

Background: Aromatic L-amino acid decarboxylase (AADC) deficiency is a rare life-threatening inborn error of neurotransmitter biosynthesis. It is characterized by deficient biosynthesis of neurotransmitters dopamine and serotonin, leading to catecholamines deficiency and sympathetic deprivation, while the parasympathetic system remains functional. Since 2012, gene therapy has led to clinical improvements in symptoms and motor function with a severe phenotype.

View Article and Find Full Text PDF

Objective: Unilateral biportal endoscopic discectomy (UBE) is an emerging and minimally invasive surgeryfor lumbar spinal degenerative disease. However, the efficacy, safety and the radiological changes of dural sac and paraspinal muscle of UBE compared with the conventional percutaneous transforaminal endoscopic discectomy (PTED) remains to be determined. The purpose of the study was to comprehensively compare the clinical efficacy between UBE and PTED in the surgical treatment of lumbar spinal degenerative disease.

View Article and Find Full Text PDF

Background: Lichtenstein hernia repair is a common surgical procedure. Previously, combined rectus sheath (RS) and transversus abdominis plane (TAP) blocks have been shown to be beneficial in laparoscopic inguinal hernia surgery. Our hypothesis is that combining the two blocks will also be beneficial in open Lichtenstein hernioplasty day-case procedures.

View Article and Find Full Text PDF

This study evaluates the feasibility of Apple Vision Pro goggles as an augmented reality (AR) surgical navigation tool for laparoscopic-assisted ultrasound-guided radiofrequency ablation (RFA) of liver tumors. Traditional RFA is effective but challenging due to the integration of multiple imaging modalities. The primary aim of this research is to assess how Vision Pro goggles can enhance the surgical navigation process during RFA, improving tumor localization and the overall effectiveness of the procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!