A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and feasibility of biventricular devices reuse in general and elderly population--a single-center retrospective cohort study. | LitMetric

Safety and feasibility of biventricular devices reuse in general and elderly population--a single-center retrospective cohort study.

Clin Interv Aging

Department of Cardiology, "Victor Babeş" University of Medicine and Pharmacy, Timişoara, Romania ; Cardiology Clinic, Institute of Cardiovascular Medicine, Timişoara, Romania.

Published: April 2016

Introduction: Cardiac resynchronization therapy (CRT) is known to have very important beneficial effects on heart failure patients. Unfortunately, biventricular implantable cardiac devices (CRT devices), through which this therapy is implemented, are very expensive and sometimes hard to achieve, especially in underdeveloped/developing economies, making this an important problem of public health. As a possible solution, CRT reuse is of great interest nowadays, but unlike simple devices, data in the literature are scarce about biventricular device reuse.

Aim: To address safety concerns, we aimed to analyze infection burden in the general and elderly population and also early battery depletion and generator malfunction of resterilized biventricular devices compared to new devices.

Methods: A cohort of 261 CRT patients (286 devices), who underwent implantation between 2000 and 2014, was retrospectively analyzed. The study group included 115 patients and 127 resterilized devices, that was divided into a subgroup of 69 elderly patients (≥60 years) and 74 devices and a subgroup of 47 younger patients (<60 years) and 53 devices, and the control group included 146 patients and 159 new devices. The groups were compared using a multivariate logistic regression model.

Results: A number of 12 (4.2%) infectious complications were encountered, five (3.9%) in the study group and seven (4.4%) in the control group (odds ratio, 2.83 [0.59-13.44], P=0.189), one (1.3%) in the elderly and four (7.5%) in the younger subgroup (odds ratio, 3.80 [0.36-40.30], P=0.266), with no statistically significant difference between them. There was only one case of early battery depletion, after 17 months, in one study group patient. No generator malfunction was detected.

Conclusion: Reuse of biventricular cardiac implantable electronics seems feasible and safe in both the general population and the elderly population, and it could be a promising alternative when new devices cannot be obtained in a safe period of time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541561PMC
http://dx.doi.org/10.2147/CIA.S88805DOI Listing

Publication Analysis

Top Keywords

devices
8
biventricular devices
8
general elderly
8
patients
5
safety feasibility
4
biventricular
4
feasibility biventricular
4
devices reuse
4
reuse general
4
elderly population--a
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!