Background: Unstable pelvic fractures are complex and serious injuries. Selection of a fixation method for these fractures remains a challenging problem for orthopedic surgeons. This study aimed to compare the stability of Tile C pelvic fractures fixed with two iliosacral (IS) screws and minimally invasive adjustable plate (MIAP) combined with one IS screw.

Methods: This study was a biomechanical experiment. Six embalmed specimens of the adult pelvis were used. The soft tissue was removed from the specimens, and the spines from the fourth lumbar vertebra to the proximal one-third of both femurs were retained. The pubic symphysis, bilateral sacroiliac joints and ligaments, bilateral hip joints, bilateral sacrotuberous ligaments, and bilateral sacrospinous ligaments were intact. Tile C pelvic fractures were made on the specimens. The symphysis pubis was fixed with a plate, and the fracture on the posterior pelvic ring was fixed with two kinds of internal fixation in turn. The specimens were placed in a biomechanical machine at a standing neutral posture. A cyclic vertical load of up to 500 N was applied, and displacement was recorded. Shifts in the fracture gap were measured by a grating displacement sensor.

Statistical Analysis Used: Paired-samples t-test.

Results: Under the vertical load of 100, 200, 300, 400, and 500 N, the average displacement of the specimens fixed with MIAP combined with one IS screw was 0.46, 0.735, 1.377, 1.823, and 2.215 mm, respectively, which was significantly lower than that of specimens fixed with two IS screws under corresponding load (P < 0.05). Under the vertical load of 500 N, the shift in the fracture gap of specimens fixed with MIAP combined with one IS screw was 0.261 ± 0.095 mm, and that of specimens fixed with two IS screws was 0.809 ± 0.170 mm. The difference was significant (P < 0.05).

Conclusion: The stability of Tile C pelvic fractures fixed with MIAP combined with one IS screw was better than that fixed with two IS screws.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4733801PMC
http://dx.doi.org/10.4103/0366-6999.163377DOI Listing

Publication Analysis

Top Keywords

pelvic fractures
16
miap combined
16
specimens fixed
16
tile pelvic
12
vertical load
12
fixed miap
12
combined screw
12
fixed screws
12
fixed
9
kinds internal
8

Similar Publications

Avascular necrosis (AVN) of the hip, a rare cause of pelvic pain in the third trimester of pregnancy, often presents with nonspecific symptoms that resemble common musculoskeletal conditions. This ambiguity, coupled with concerns about the safety of magnetic resonance imaging (MRI) during pregnancy, can hinder timely diagnosis. We report a unique case of a 32-year-old primigravida diagnosed with a hip fracture and bilateral AVN of the femoral head in the immediate postpartum period, a complication seemingly not previously documented in pregnant patients.

View Article and Find Full Text PDF

Computed tomography plays an ever-increasing role in the management of fractures and dislocations due to its capability in efficiently providing multiplanar reformats and 3-dimensional volume rendered images. It can reveal findings that are occult on plain radiography and therefore allow for more accurate decision making with regard to fracture classification and management. Clinical radiologists play a critical role in facilitating the processing of imaging to provide adequate image reformats in the desired planes, producing 3 dimensional images but most crucially identifying pertinent findings, which will contribute between the selection of nonoperative and operative management and potentially influence surgical technique.

View Article and Find Full Text PDF

[The best preferable sagittal vertical axis for the ankylosis spondylitis with thoracolumbar kyphosis following one-level pedicle subtraction osteotomy under different cervical range of motion].

Zhonghua Yi Xue Za Zhi

January 2025

Division of Spine Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing210008, China.

To analyze the influence of cervical range of motion on the preferable sagittal vertical axis in ankylosis spondylitis (AS)-related thoracolumbar kyphosis following single-level pedicle subtraction osteotomy (PSO). The clinical data of sixty-five AS patients who underwent single-level PSO from February 2012 to November 2018 in the Drum Tower Hospital of Nanjing University Medical School were retrospectively reviewed. Of the patients, 59 were males and 6 were females with a mean age of (34.

View Article and Find Full Text PDF

Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.

View Article and Find Full Text PDF

Objective: By comparing the hip arthroplasty parameters planned with the AIHIP three-dimensional simulation surgery system, this study analyzes the accuracy of the new femoral-side "shoulder-to-shoulder" artificial anatomical marker positioning method in femoral-side prosthesis implantation and the prevention of leg length discrepancy in hip arthroplasty.

Methods: A retrospective collection of 47 patients who underwent initial total hip arthroplasty at our hospital from August 2020 to December 2022 and met the inclusion and exclusion criteria was used as the study subjects. The average age was 67.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!