A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cycle-dependent in vitro wear performance of dental ceramics after clinical surface treatments. | LitMetric

Aim: To investigate the two-body wear performance of dental ceramics after different clinical surface treatments as a function of number of wear cycles.

Material And Methods: Standardized specimens (n=72/material) were prepared from two different zirconia ceramics, a veneering porcelain, and a lithiumdisilicate glass ceramic. Specimens were progressively glazed, ground, and polished. After each treatment step 24 specimens per material were kept at the obtained surface state. Steatite and human enamel specimens served as reference materials. Two-body wear tests were performed with steatite spheres as antagonists in a pin-on-block design (50N, 1.6 Hz, lateral movement: 1mm, mouth opening: 2mm) under simultaneous thermal cycling (5/55 °C, 2 min/cycle). For investigating the dynamic evolution of the wear process, 9 groups per material (n=8/group) were defined, differing in surface state (glazed, ground, and polished) and number of chewing cycles (40T, 80T, and 120T; T: ×1000): glazed 40T, glazed 80T, glazed 120T, ground 40T, ground 80T, ground 120T, polished 40T, polished 80T, polished 120T. Surface roughness, wear depth of the specimens and relative wear area of the steatite antagonists were determined using an optical 3D laser scanning microscope. SEM evaluation was done. Mean values and standard deviations were calculated and statistically analyzed (one-way ANOVA, post-hoc Bonferroni, α=0.05).

Results: Veneering and lithiumdisilicate ceramics showed higher wear depths than zirconia ceramics (p<0.05). Wear of veneering and lithiumdisilicate ceramics and their antagonists increased with wear cycles but was only marginally influenced by the initial surface state. Wear of zirconia was not influenced by wear cycles but antagonists of zirconia showed a cycle-dependent wear increase. Polished zirconia surfaces showed lowest wear for material and antagonist. Wear mechanism of common ceramics was characterized by abrasive wear. Zirconia in contrast showed a superficial cyclic shifting of worn material of the antagonist.

Conclusions: Wear of zirconia and standard ceramics showed different wear performances, strongly influenced by surface treatments as well as number of wear cycles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2015.08.009DOI Listing

Publication Analysis

Top Keywords

wear
8
wear performance
8
performance dental
8
dental ceramics
8
ceramics clinical
8
clinical surface
8
surface treatments
8
two-body wear
8
zirconia ceramics
8
glazed ground
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!