Low relative error in consumer-grade GPS units make them ideal for measuring small-scale animal movement patterns.

PeerJ

Harvard Forest, Harvard University , Petersham, MA , United States of America ; Department of Botany and Plant Pathology, Oregon State University, Corvallis, OR , United States of America.

Published: August 2015

Consumer-grade GPS units are a staple of modern field ecology, but the relatively large error radii reported by manufacturers (up to 10 m) ostensibly precludes their utility in measuring fine-scale movement of small animals such as insects. Here we demonstrate that for data collected at fine spatio-temporal scales, these devices can produce exceptionally accurate data on step-length and movement patterns of small animals. With an understanding of the properties of GPS error and how it arises, it is possible, using a simple field protocol, to use consumer grade GPS units to collect step-length data for the movement of small animals that introduces a median error as small as 11 cm. These small error rates were measured in controlled observations of real butterfly movement. Similar conclusions were reached using a ground-truth test track prepared with a field tape and compass and subsequently measured 20 times using the same methodology as the butterfly tracking. Median error in the ground-truth track was slightly higher than the field data, mostly between 20 and 30 cm, but even for the smallest ground-truth step (70 cm), this is still a signal-to-noise ratio of 3:1, and for steps of 3 m or more, the ratio is greater than 10:1. Such small errors relative to the movements being measured make these inexpensive units useful for measuring insect and other small animal movements on small to intermediate scales with budgets orders of magnitude lower than survey-grade units used in past studies. As an additional advantage, these units are simpler to operate, and insect or other small animal trackways can be collected more quickly than either survey-grade units or more traditional ruler/gird approaches.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4548486PMC
http://dx.doi.org/10.7717/peerj.1205DOI Listing

Publication Analysis

Top Keywords

gps units
12
small animals
12
small
9
consumer-grade gps
8
movement patterns
8
movement small
8
median error
8
insect small
8
small animal
8
survey-grade units
8

Similar Publications

Analyzing performance in rowing, e.g., analyzing force and power output profiles produced either on ergometer or on boat, is a priority for trainers and athletes.

View Article and Find Full Text PDF

Background: General practitioners (GPs) and primary care units collaborate with Prevention Departments (PDs) to improve immunization by participating in vaccination campaigns, sharing tools, and implementing educational programs to raise patient awareness. This review aimed to identify effective strategies for involving GPs in PD vaccination practices.

Methods: A systematic review following PRISMA guidelines was conducted on MEDLINE, TripDatabase, ClinicalTrials, CINAHL, and Cochrane up to January 2024 to identify full-text studies in English evaluating the effectiveness of GP involvement.

View Article and Find Full Text PDF
Article Synopsis
  • This study examines how patient care differs among general practitioners in Upper Austria, focusing on various organizational forms like single practices, group practices, and primary health care units.
  • Data collection involved analyzing patient demographics, prescription patterns, and service offerings, revealing that single practices tend to prescribe more medications for chronic conditions while group practices are more common in populated areas.
  • The findings highlight inconsistencies in documenting patient visit reasons and emphasize the importance of standardized practices for better outbreak management in outpatient medicine.
View Article and Find Full Text PDF

Purpose: This study investigated the mechanisms of neuromuscular fatigue and recovery in quadriceps and hamstring muscles following soccer match-play and typical training sessions dedicated to the physical development of players.

Methods: Fifteen male professional academy soccer players completed at different visits a 90-minute simulated soccer match-play (MATCH) and four training sessions modulating the metabolic nature (HIIT vs. SPRINT) and the mechanical load (number of changes of direction [COD]).

View Article and Find Full Text PDF

Underwater simultaneous localization and mapping (SLAM) has significant challenges due to the complexities of underwater environments, marked by limited visibility, variable conditions, and restricted global positioning system (GPS) availability. This study provides a comprehensive analysis of sensor fusion techniques in underwater SLAM, highlighting the amalgamation of proprioceptive and exteroceptive sensors to improve UUV navigational accuracy and system resilience. Essential sensor applications, including inertial measurement units (IMUs), Doppler velocity logs (DVLs), cameras, sonar, and LiDAR (light detection and ranging), are examined for their contributions to navigation and perception.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!