A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability and validity of an ultrasound-based imaging method for measuring interspinous process distance in the lumbar spine using two different index points. | LitMetric

[Purpose] This study assessed the reliability and validity of an ultrasound-based imaging method for measuring the interspinous process distance in the lumbar spine using two different index points. [Subjects and Methods] Ten healthy males were recruited. Five physical therapy students participated in this study as examiners. The L2-L3 interspinous distance was measured from the caudal end of the L2 spinous process to the cranial end of the L3 spinous process (E-E measurement) and from the top of the L2 spinous process to the top of the L3 spinous process (T-T measurement). Intraclass correlation coefficients were calculated to estimate the relative reliability. Validity was assessed using a model resembling the living human body. [Results] The reliability study showed no difference in intra-rater reliability between the two measurements. However, the E-E measurement showed higher inter-rater reliability than the T-T measurement (Intraclass correlation coefficients: 0.914 vs. 0.725). Moreover, the E-E measurement method had good validity (Intraclass correlation coefficients: 0.999 and 95% confidence interval for minimal detectable change: 0.29 mm). [Conclusion] These results demonstrate the high reliability and validity of ultrasound-based imaging in the quantitative assessment of lumbar interspinous process distance. Of the two methods, the E-E measurement method is recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4540874PMC
http://dx.doi.org/10.1589/jpts.27.2333DOI Listing

Publication Analysis

Top Keywords

reliability validity
16
spinous process
16
e-e measurement
16
validity ultrasound-based
12
ultrasound-based imaging
12
interspinous process
12
process distance
12
intraclass correlation
12
correlation coefficients
12
imaging method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!