A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Screening for Intermediately Vancomycin-Susceptible and Vancomycin-Heteroresistant Staphylococcus aureus by Use of Vancomycin-Supplemented Brain Heart Infusion Agar Biplates: Defining Growth Interpretation Criteria Based on Gold Standard Confirmation. | LitMetric

BHI agars supplemented with vancomycin 4 (BHI-V4) and 3 (BHI-V3) mg/liter have been proposed for screening vancomycin intermediately susceptible Staphylococcus aureus (VISA) and heteroresistant (hVISA) phenotypes, respectively, but growth interpretation criteria have not been established. We reviewed the growth results (CFU) during population analysis profile-area under the curve (PAP-AUC) of consecutive methicillin-resistant Staphylococcus aureus (MRSA) blood isolates, which were saved intermittently between 1996 and 2012. CFU counts on BHI-V4 and BHI-V3 plates were stratified according to PAP-AUC interpretive criteria: <0.90 (susceptible [S-MRSA]), 0.90 to 1.3 (hVISA), and >1.3 (VISA). CFU cutoffs that best predict VISA and hVISA were determined with the use of receiver operating characteristic (ROC) curves. Mu3, Mu50, and methicillin-susceptible S. aureus (MSSA) controls were included. We also prospectively evaluated manufacturer-made BHI-V3/BHI-V4 biplates for screening of 2010-2012 isolates. The PAP-AUC of 616 clinical samples was consistent with S-MRSA, hVISA, and VISA in 550 (89.3%), 48 (7.8%), and 18 (2.9%) instances, respectively. For VISA screening on BHI-V4, a cutoff of 2 CFU/droplet provided 100% sensitivity and 97.7% specificity. To distinguish VISA from hVISA, a cutoff of 16 CFU provided 83.3% sensitivity and 94.7% specificity; the specificity was lowered to 89.5% with a 12-CFU cutoff. For detecting hVISA/VISA on BHI-V3, a 2-CFU/droplet cutoff provided 98.5% sensitivity and 93.8% specificity. These results suggest that 2-CFU/droplet cutoffs on BHI-V4 and BHI-V3 best approximate VISA and hVISA gold standard confirmation, respectively, with minimal overlap in samples with borderline PAP-AUC. Simultaneous screening for VISA/hVISA on manufacturer-made BHI-V4/BHI-V3 biplates is easy to standardize and may reduce the requirement for PAP-AUC confirmation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4609695PMC
http://dx.doi.org/10.1128/JCM.01620-15DOI Listing

Publication Analysis

Top Keywords

staphylococcus aureus
12
bhi-v4 bhi-v3
12
visa hvisa
12
growth interpretation
8
interpretation criteria
8
gold standard
8
standard confirmation
8
visa
7
screening
5
hvisa
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!