I report my experience using a new tear duct tube made from medical grade Teflon (Dupont) both as a bypass tube in situations in which a Pyrex Jones tube (Gunther Weiss, Portland Oregon) traditionally would be used, as well as a stent through the lower canaliculus, or as a bypass tube placed either through the lower canaliculus or at the inner canthus in connection with canaliculus laceration repair. After relatively brief follow-up, these Teflon tubes appeared to be associated with fewer complications than the Jones tube and in certain instances to offer other advantages as well.
Download full-text PDF |
Source |
---|
Natl J Maxillofac Surg
November 2024
Department of ENT, All India Institute of Medical Sciences (AIIMS), Deoghar, Jharkhand, India.
Exploring diverse biomaterials and implants in the ear, nose, and throat by understanding adverse effects and post-usage events. Literature was obtained from Scopus, PubMed, Google Scholar, and Web of Science. A comprehensive analysis was conducted on original research studies, case reports, and case series spanning from December 2010 to May 2022.
View Article and Find Full Text PDFHeliyon
October 2024
Environmental Sciences and Technology Research Center, Department of Environmental Health Engineering, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Artif Organs
January 2025
Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA.
Background: To accommodate a wider range of medical device sizes, a larger in vitro flow loop thrombogenicity test system using 9.5 -mm inner diameter (ID) tubing was developed and evaluated based on our previously established 6.4 -mm ID tubing system.
View Article and Find Full Text PDFWorld J Gastroenterol
August 2024
Department of Infection Control, West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, China.
Background: Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels.
Aim: To develop a spray flushing system to achieving effective cleaning of the working channels while minimizing damage.
Methods: This prospective study included 60 used endoscopes and 60 Teflon tubes randomly divided into a control group ( = 30) and an experimental group ( = 30).
Polymers (Basel)
June 2024
Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH 45435, USA.
The 6935M Sprint Quattro Secure S and 6947M Sprint Quattro Secure are high voltage leads designed to administer a maximum of 40 joules of energy for terminating ventricular tachycardia or ventricular fibrillation. Both leads utilize silicone insulation and a polyurethane outer coating. The inner coil is shielded with polytetrafluoroethylene (PTFE) tubing, while other conductors are enveloped in ethylene tetrafluoroethylene (ETFE), contributing to the structural integrity and functionality of these leads.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!