A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of real-time field control in T2 *-Weighted head MRI at 7T. | LitMetric

Purpose: Real-time field control can serve to reduce respiratory field perturbations during T2 * imaging at high fields. This work investigates the effectiveness of this approach in relation to key variables such as patient physique, breathing patterns, slice location, and the choice of sequence.

Methods: To cover variation in physical constitution and breathing behavior, volunteers with a wide range of body-mass-indices were asked to breathe either normally or deeply during T2 *-weighted image acquisition at 7T. Ensuing field fluctuation was countered by real-time field control or merely recorded in reference experiments. The impact of the control system on image quality was assessed by classifying and grading artifacts related to field fluctuation.

Results: The amplitude of respiratory field changes and related artifacts were generally stronger for subjects with higher body-mass-index and for lower slices. Field control was found effective at mitigating all five types of artifacts that were studied. Overall image quality was systematically improved. Residual artifacts in low slices are attributed to insufficient spatial order of the control system.

Conclusion: Real-time field control was found to be a robust means of countering respiratory field perturbations in variable conditions encountered in high-field brain imaging. Reducing net fluctuation, it generally expands the feasibility of high-field T2 * imaging toward challenging patients and brain regions. Magn Reson Med 76:430-439, 2016. © 2015 Wiley Periodicals, Inc.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25838DOI Listing

Publication Analysis

Top Keywords

field control
20
real-time field
16
respiratory field
12
field
10
field perturbations
8
image quality
8
control
7
utility real-time
4
control *-weighted
4
*-weighted head
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!