A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility and Diagnostic Accuracy of Supersonic Shear-Wave Elastography for the Assessment of Liver Stiffness and Liver Fibrosis in Children: A Pilot Study of 96 Patients. | LitMetric

Feasibility and Diagnostic Accuracy of Supersonic Shear-Wave Elastography for the Assessment of Liver Stiffness and Liver Fibrosis in Children: A Pilot Study of 96 Patients.

Radiology

From the Departments of Pediatric Radiology (S.F.A., L.C., D.P.), Pediatric Hepatology (E.G.), and Epidemiology (G.A., B.D.), Hôpital Bicêtre, Hôpitaux Universitaires Paris Sud, Assistance Publique Hôpitaux de Paris, Université Paris Sud, 78 rue du Général Leclerc, 94275 Le Kremlin Bicêtre, France; Departments of Pathology (M.F.) and Adult Radiology (J.M.C.), Hôpital Necker, Assistance Publique Hôpitaux de Paris, Université Paris V, Assistance Publique Hôpitaux de Paris, Paris, France; and Institut Langevin, ESPCI ParisTech, CNRS UMR7587, INSERM U979, Paris, France (J.L.G., M.T.).

Published: February 2016

Purpose: To evaluate the feasibility of using supersonic shear-wave elastography (SSWE) in children and normal values of liver stiffness with the use of control patients of different ages (from neonates to teenagers) and the diagnostic accuracy of supersonic shear wave elastography for assessing liver fibrosis by using the histologic scoring system as the reference method in patients with liver disease, with a special concern for early stages of fibrosis.

Materials And Methods: The institutional review board approved this prospective study. Informed consent was obtained from parents and children older than 7 years. First, 51 healthy children (from neonate to 15 years) were analyzed as the control group, and univariate and multivariate comparisons were performed to study the effect of age, transducer, breathing condition, probe, and position on elasticity values. Next, 45 children (from 1 month to 17.2 years old) who underwent liver biopsy were analyzed. SSWE measurements were obtained in the same region of the liver as the biopsy specimens. Biopsy specimens were reviewed in a blinded manner by a pathologist with the use of METAVIR criteria. The areas under the receiver operating characteristics curve (AUCs) were calculated for patients with fibrosis stage F0 versus those with stage F1-F2, F2 or higher, F3 or higher, and F4 or higher.

Results: A successful rate of SSWE measurement was 100% in 96 patients, including neonates. Liver stiffness values were significantly higher when an SC6-1 probe (Aixplorer; SuperSonic Imagine SA, Aix-enProvence, France) was used than when an SL15-4 probe (Aixplorer) was used (mean ± standard deviation, 6.94 kPa ± 1.42 vs 5.96 kPa ± 1.31; P = .006). There was no influence of sex, the location of measurement, or respiratory status on liver elasticity values (P = .41-.93), although the power to detect such a difference was low. According to the degree of liver fibrosis at liver biopsy, 88.5%-96.8% of patients were correctly classified, with AUCs of 0.90-0.98 (95% confidence interval [CI]: 0.8, 1.0). The AUC for patients with stage F0 versus stage F1-F2 was 0.93 (95% CI: 0.87, 0.99).

Conclusion: SSWE allows accurate assessment of liver fibrosis, even in children with early stage (F1-F2) disease, and the choice of transducer influences liver stiffness values.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2015142815DOI Listing

Publication Analysis

Top Keywords

liver stiffness
16
liver fibrosis
16
liver
13
liver biopsy
12
stage f1-f2
12
diagnostic accuracy
8
accuracy supersonic
8
supersonic shear-wave
8
shear-wave elastography
8
assessment liver
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!