Biomechanical Study of the Digital Flexor Tendon Sliding Lengthening Technique.

J Hand Surg Am

Department of Orthopedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.

Published: October 2015

Purpose: To compare the mechanical properties of sliding lengthening (SL) and Z-lengthening (ZL) for flexor tendon elongation used for conditions such as Volkmann contracture, cerebral palsy, and poststroke spasticity.

Methods: We harvested 56 flexor tendons, including flexor pollicis longus tendons, flexor digitorum superficialis tendons (zones II to IV), and flexor digitorum profundus tendons (zones II to V) from 24 upper limbs of 12 fresh cadavers. Each tendon was harvested together with its homonymous tendon from the opposite side of the cadaver and paired. We used 28 pairs of tendons and divided them randomly into 4 groups depending on the lengthening distance (20 or 30 mm) and type of stitching (single or double mattress sutures). Then we divided each pair into either the SL or ZL group. Each group was composed of 7 specimens. The same surgeon lengthened all tendons and stitched them with 2-0 polyester sutures. We tested biomechanical tensile strength immediately after completing lengthening and suturing in each group.

Results: Ultimate tensile strengths were: 23 N for the SL 20-mm lengthening and single mattress suture and 7 N for the ZL; 25 N for the SL 20-mm lengthening and double mattress suture and 10 N for the ZL; 15 N for the SL 30-mm lengthening and single mattress suture and 8 N for the ZL; and 18 N for the SL 30-mm lengthening and double mattress suture and 10 N for the ZL.

Conclusions: The SL technique may be a good alternative to the ZL technique because it provides higher ultimate tensile strength.

Clinical Relevance: Because of its higher ultimate tensile strength, the SL technique may allow for earlier rehabilitation and reduced risk of postoperative complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2015.06.120DOI Listing

Publication Analysis

Top Keywords

mattress suture
16
double mattress
12
ultimate tensile
12
flexor tendon
8
lengthening
8
sliding lengthening
8
flexor digitorum
8
tendons zones
8
tensile strength
8
20-mm lengthening
8

Similar Publications

Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.

View Article and Find Full Text PDF

Direct repair of ulnar collateral ligament (UCL) injuries with suture augmentation has been successful in properly selected patients lacking chronic attritional wear of the medial elbow. Described is a Speed-Fix technique for direct UCL repair using SutureTape, with Brace augmentation. The Speed-Fix repair technique uses an inverted mattress knotless repair with a knotless SwiveLock anchor and FiberTape suture, which allows for theoretical compression at the repair site.

View Article and Find Full Text PDF

Inside-out repair of meniscal tears is the gold standard surgical approach; however, its use is limited by the need for a posterior incision and neurovascular risk. In this Technical Report, we present details of the all-inside arthroscopic tie-grip approach for repairing a radial tear of the midbody of the lateral meniscus using an all-inside device (TRUESPAN) and a slotted cannula. In contrast to the inside-out approach, this technique helps reduce surgical invasiveness and provides stable fixation as the vertical mattress sutures bundle the circumferential fibers and act as rip stops for the horizontal sutures.

View Article and Find Full Text PDF

Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.

Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.

View Article and Find Full Text PDF

Background: Sleeve gastrectomy (SG) is the most frequently performed bariatric surgery worldwide, offering effective weight loss and improvement in metabolic conditions. However, one of its major complications is the exacerbation or development of gastroesophageal reflux disease (GERD), affecting over 30% of patients. While Roux-en-Y gastric bypass (RYGB) is often the preferred alternative for patients with pre-existing GERD, it may not be suitable for all patients due to contraindications or patient preference.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!