Mean centering of double divisor ratio spectra, a novel spectrophotometric method for analysis of ternary mixtures.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Analytical Chemistry, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, 11562 Cairo, Egypt.

Published: January 2016

A novel spectrophotometric method was developed for determination of ternary mixtures without previous separation, showing significant advantages over conventional methods. The new method is based on mean centering of double divisor ratio spectra. The mathematical explanation of the procedure is illustrated. The method was evaluated by determination of model ternary mixture and by the determination of Amlodipine (AML), Aliskiren (ALI) and Hydrochlorothiazide (HCT) in laboratory prepared mixtures and in a commercial pharmaceutical preparation. For proper presentation of the advantages and applicability of the new method, a comparative study was established between the new mean centering of double divisor ratio spectra (MCDD) and two similar methods used for analysis of ternary mixtures, namely mean centering (MC) and double divisor of ratio spectra-derivative spectrophotometry (DDRS-DS). The method was also compared with a reported one for analysis of the pharmaceutical preparation. The method was validated according to the ICH guidelines and accuracy, precision, repeatability and robustness were found to be within the acceptable limits.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2015.07.109DOI Listing

Publication Analysis

Top Keywords

centering double
16
double divisor
16
divisor ratio
16
ratio spectra
12
ternary mixtures
12
novel spectrophotometric
8
spectrophotometric method
8
analysis ternary
8
pharmaceutical preparation
8
method
7

Similar Publications

Comparison of mechanical properties and shaping performance of ProGlider and ProTaper ultimate slider.

BMC Oral Health

January 2025

Department of Conservative Dentistry, College of Dentistry, Kyung Hee University, 26-6, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02453, Republic of Korea.

Background: This study aims to compare design, phase transformation behavior, and torsional resistance of the ProGlider (PG) and ProTaper ultimate slider (PUS) and to compare the performance of two files in the glide-path preparation of a double-curved artificial canal.

Methods: Scanning electron microscopy, micro-computed tomography, and differential scanning calorimetry were used to characterize the samples. A torsional resistance test was performed to obtain ultimate strength and distortion angle.

View Article and Find Full Text PDF

The preservation of the original configurations of root canals during endodontic preparation is crucial for treatment success. Nickel-titanium (NiTi) rotary systems have been refined to optimize canal shaping while minimizing iatrogenic errors. This study aimed to evaluate and compare the shaping efficacy of the novel R-Motion (RM) and the established WaveOne Gold (WG) systems using micro-computed tomography (micro-CT).

View Article and Find Full Text PDF

This case report describes the clinical, radiographic, and histopathological features of a self-limiting mandibular swelling in a juvenile, large breed dog with a diagnosis of mandibular periostitis ossificans (MPO). This is a pathologic syndrome of immature large breed dogs that presents with a unilateral, nonpainful, caudal mandibular swelling centering on the erupting first molar tooth. This condition affects dogs with a median age of approximately 4 months.

View Article and Find Full Text PDF
Article Synopsis
  • The article reviews different methods to measure the shaping ability of endodontic rotary files, focusing on the choice of sample types (extracted teeth vs. simulated blocks) and imaging techniques.
  • A literature search identified 86 relevant studies from a large pool, noting that the majority used extracted teeth, while a smaller portion used simulated root canals; various imaging methods were employed to evaluate performance.
  • The review concludes that Micro-Computed Tomography (MCT) and its advanced variants are generally superior for assessing root canal instrumentation quality, discussing the advantages and limitations of other methods and emphasizing the need for improved study designs in the field.
View Article and Find Full Text PDF

Introduction: This paper investigates the operational stability of lactate biosensors, crucial devices in various biomedical and biotechnological applications. We detail the construction of an amperometric transducer tailored for lactate measurement and outline the experimental setup used for empirical validation.

Methods: The modeling framework incorporates Brown and Michaelis-Menten kinetics, integrating both distributed and discrete delays to capture the intricate dynamics of lactate sensing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!