A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of broad-scope assays of nucleotide sugar-dependent glycosyltransferases. | LitMetric

Comparison of broad-scope assays of nucleotide sugar-dependent glycosyltransferases.

Anal Biochem

Institute of Biotechnology and Biochemical Engineering, Graz University of Technology, A-8010 Graz, Austria; Austrian Centre of Industrial Biotechnology, A-8010 Graz, Austria. Electronic address:

Published: December 2015

Glycosyltransferases (GTs) are abundant in nature and diverse in their range of substrates. Application of GTs is, however, often complicated by their narrow substrate specificity. GTs with tailored specificities are highly demanded for targeted glycosylation reactions. Engineering of such GTs is, however, restricted by lack of practical and broad-scope assays currently available. Here we present an improvement of an inexpensive and simple assay that relies on the enzymatic detection of inorganic phosphate cleaved from nucleoside phosphate products released in GT reactions. This phosphatase-coupled assay (PCA) is compared with other GT assays: a pH shift assay and a commercially available immunoassay in Escherichia coli cell-free extract (CE). Furthermore, we probe PCA with three GTs with different specificities. Our results demonstrate that PCA is a versatile and apparently general GT assay with a detection limit as low as 1 mU. The detection limit of the pH shift assay is roughly 4 times higher. The immunoassay, by contrast, detected only nucleoside diphosphates (NDPs) but had the lowest detection limit. Compared with these assays, PCA showed superior robustness and, therefore, appears to be a suitable general screening assay for nucleotide sugar-dependent GTs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ab.2015.08.012DOI Listing

Publication Analysis

Top Keywords

detection limit
12
broad-scope assays
8
nucleotide sugar-dependent
8
compared assays
8
shift assay
8
gts
6
assay
6
comparison broad-scope
4
assays
4
assays nucleotide
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!