Characteristic length of the knotting probability revisited.

J Phys Condens Matter

Department of Physics, Graduate School of Humanities and Sciences, Ochanomizu University 2-1-1 Ohtsuka, Bunkyo-ku, Tokyo 112-8610, Japan.

Published: September 2015

We present a self-avoiding polygon (SAP) model for circular DNA in which the radius of impermeable cylindrical segments corresponds to the screening length of double-stranded DNA surrounded by counter ions. For the model we evaluate the probability for a generated SAP with N segments having a given knot K through simulation. We call it the knotting probability of a knot K with N segments for the SAP model. We show that when N is large the most significant factor in the knotting probability is given by the exponentially decaying part exp(-N/NK), where the estimates of parameter NK are consistent with the same value for all the different knots we investigated. We thus call it the characteristic length of the knotting probability. We give formulae expressing the characteristic length as a function of the cylindrical radius rex, i.e. the screening length of double-stranded DNA.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0953-8984/27/35/354104DOI Listing

Publication Analysis

Top Keywords

knotting probability
16
characteristic length
12
length knotting
8
sap model
8
screening length
8
length double-stranded
8
double-stranded dna
8
probability
5
knotting
4
probability revisited
4

Similar Publications

Objective: To investigate the pregnancy outcomes and independent risk factors associated with true knots of the umbilical cord (TKUC).

Materials And Methods: This retrospective study included 8140 deliveries at Fujian Maternal and Child Health Hospital from 2017 to 2021. Mothers and newborns diagnosed with TKUC were included in the TKUC group, while the others were included in the control group.

View Article and Find Full Text PDF

Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.

Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.

View Article and Find Full Text PDF
Article Synopsis
  • The paper discusses how polymer chains in melts and θ-chains behave like random walks, although this model fails to account for their complex topologies and knotting.
  • Researchers used simulations to show that these two types of chains share similar structural and topological features, including knotting probabilities and sizes, which ideal chain models do not accurately predict.
  • The study concludes that while both types of chains have idealized behaviors, real chains exhibit corrections influenced by their flexibility, particularly noting that smaller knots are suppressed, especially in more flexible polymers.
View Article and Find Full Text PDF

Introduction: burst abdomen is a preventable complication of caesarean section that carries an increased risk of maternal death, especially in developing countries including Tanzania. The study aimed to identify the risk factors and high-risk patients for burst abdomen at Muhimbili National Hospital in Tanzania.

Methods: a case-control study was performed at Muhimbili National Hospital in Dar es Salaam from 2 April to 27 December 2019.

View Article and Find Full Text PDF

Objective: This study aims to assess the performance of various scoring systems in predicting the 28-day mortality of patients with aortic aneurysms (AA) admitted to the intensive care unit (ICU).

Methods: We utilized data from the Medical Information Mart for Intensive Care-IV (MIMIC-IV) to perform a comparative analysis of various predictive systems, including the Glasgow Aneurysm Score (GAS), Simplified Acute Physiology Score (SAPS) III, SAPS II, Logical Organ Dysfunction System (LODS), Sequential Organ Failure Assessment (SOFA), Systemic Inflammatory Response Syndrome (SIRS), and The Oxford Acute Illness Severity Score (OASIS). The discrimination abilities of these systems were compared using the area under the receiver operating characteristic curve (AUROC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!