Background: Whether the composition of palatal connective tissue grafts (CTGs) varies depending on donor site or harvesting technique in terms of relative amounts of fibrous connective tissue (CT) and fatty/glandular tissue (FGT) is currently unknown and is histologically assessed in the present study.

Methods: In 10 fresh human cadavers, tissue samples were harvested in the anterior and posterior palate and in areas close to (marginal) and distant from (apical) the mucosal margin. Mucosal thickness, lamina propria thickness (defined as the extent of subepithelial portion of the biopsy containing ≤25% or ≤50% FGT), and proportions of CT and FGT were semi-automatically estimated for the entire mucosa and for CTGs virtually harvested by split-flap (SF) preparation minimum 1 mm deep or after deepithelialization (DE).

Results: Palatal mucosal thickness, ranging from 2.35 to 6.89 mm, and histologic composition showed high interindividual variability. Lamina propria thickness (P >0.21) and proportions of CT (P = 0.48) and FGT (P = 0.15) did not differ significantly among the donor sites (anterior, posterior, marginal, apical). However, thicker palatal tissue was associated with higher FGT content (P <0.01) and thinner lamina propria (P ≤0.03). Independent of the donor site, DE-harvested CTG contained a significantly higher proportion of CT and a lower proportion of FGT than an SF-harvested CTG (P <0.04).

Conclusion: Despite high interindividual variability in terms of relative tissue composition in the hard palate, DE-harvested CTG contains much larger amounts of CT and much lower amounts of FGT than SF-harvested CTG, irrespective of the harvesting site.

Download full-text PDF

Source
http://dx.doi.org/10.1902/jop.2015.150346DOI Listing

Publication Analysis

Top Keywords

connective tissue
12
fibrous connective
8
fatty/glandular tissue
8
tissue grafts
8
harvesting technique
8
donor site
8
anterior posterior
8
mucosal thickness
8
lamina propria
8
propria thickness
8

Similar Publications

Marfan syndrome (MFS), an inherited connective tissue disorder, is caused by a mutation in the FBN1 gene. MFS is characterized by complex manifestations involving musculoskeletal, cardiovascular, and ocular systems. The usual presentation for suspecting diagnosis in an individual with aortic root disease is tall stature in addition to other features that fulfill Ghent criteria.

View Article and Find Full Text PDF

We report the case of a 15-year-old girl who presented with a 2-month history of severe fatigue and rapidly worsening myalgia. Biological tests revealed hypereosinophilia and an inflammatory syndrome. MRI showed increased signal intensity in the superficial and deep aponeurotic layers on T2-weighted images, with moderate fascia enhancement after contrast administration.

View Article and Find Full Text PDF

Joint hypermobility is a common feature in children and adolescents, often physiological and benign, but it is also a manifestation of hereditary connective tissue disorders. In pediatrics, there is a real need to differentiate Ehlers-Danlos syndrome (EDS) hypermobile type (hEDS) from benign hypermobility, in the absence of a genetic marker specific to this form of EDS. In 2023, the International Ehlers-Danlos Consortium revised the diagnostic criteria for children and adolescents, introducing the concept of hypermobility spectrum disorder.

View Article and Find Full Text PDF

Mechanisms and new advances in the efficacy of plant active ingredients in tendon-bone healing.

J Orthop Surg Res

January 2025

The First Affiliated Hospital of Baotou Medical College, Inner Mongolia University of Science and Technology, No.41 Linyin Road, Baotou, Inner Mongolia, 014010, China.

The tendon-bone interface, known as the tenosynovial union or attachment, can be easily damaged by excessive exercise or trauma. Tendon-bone healing is a significant research topic in orthopedics, encompassing various aspects of sports injuries and postoperative recovery. Surgery is the most common treatment; however, it has limited efficacy in promoting tendon-bone healing and carries a risk of postoperative recurrence, necessitating the search for more effective treatments.

View Article and Find Full Text PDF

Bioelectronic osteosynthesis plate to monitor the fracture bone healing using electric capacitive variations.

J Orthop Surg Res

January 2025

Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), University of Aveiro, Aveiro, 3810-193, Portugal.

Background: Bone fractures represent a global public health issue. Over the past few decades, a sustained increase in the number of incidents and prevalent cases have been reported, as well as in the years lived with disability. Current monitoring techniques predominantly rely on imaging methods, which can result in subjective assessments, and expose patients to unnecessary cumulative doses of radiation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!