Background And Aim: Trendelenburg positioning (TP) is a common approach used during internal jugular vein (IJV) cannulation. No evidence indicates that TP significantly increases the cross-sectional area (CSA) of the IJV or decreases the overlap between the carotid artery (CA) and the IJV in dialysis patients. The primary aim of this study was to investigate the effects of the TP on the CSA of the right IJV and on its relationship to the CA.

Methods: Thirty-seven consecutive hemodialysis patients older than 18 years of age were enrolled. We measured the CSA of the right IJV and overlap rate (at end-expiration at the level of the cricoid cartilage) between the CA and the IJV in two positions: State 0, table flat (no tilt), with the patient in the supine position; State T, in which the operating table was tilted to 15° of TP.

Results: Data were collected for all of the 37 patients enrolled in the study. The change in CSA and overlap between the CA and the IJV from the supine to the TP was not significantly different. The CSA was paradoxically decreased in 11 of 37 patients when changed from State 0 to State T.

Conclusions: TP does not significantly increase the CSA of the right IJV or decrease the overlap between the CA and the IJV in dialysis patients. In fact, in some patients, it reduces the CSA. Therefore, the use of the TP for IJV cannulation in dialysis patients can no longer be supported.

Download full-text PDF

Source
http://dx.doi.org/10.3109/0886022X.2015.1073052DOI Listing

Publication Analysis

Top Keywords

csa ijv
20
dialysis patients
16
ijv
10
trendelenburg positioning
8
internal jugular
8
jugular vein
8
cross-sectional area
8
patients
8
ijv cannulation
8
ijv dialysis
8

Similar Publications

Background And Aims: Prompt assessments and quick replacement of intravascular fluid are critical steps to resuscitate hypovolemic patients. Intravascular volume assessment by direct central venous pressure (CVP) measurement is an invasive, time-consuming, and labor-intensive procedure. Nowadays, bedside ultrasound-guided volume assessment of the internal jugular vein (IJV) or inferior vena cava (IVC) is commonly employed as a proxy for direct CVP.

View Article and Find Full Text PDF

Microgravity in spaceflight produces headward fluid shifts which probably contribute to Spaceflight-Associated Neuro-Ocular Syndrome (SANS). Developing new methods to mitigate these shifts is crucial for preventing SANS. One possible strategy is the use of self-generated lower body negative pressure (LBNP).

View Article and Find Full Text PDF

Background: Venous access in patients with obesity presents significant challenges. The success of central venous catheterisation largely depends on the cross-sectional area (CSA) of the internal jugular vein (IJV). While techniques like the Trendelenburg position have been traditionally used to increase IJV CSA, recent studies suggest its ineffectiveness in patients with obesity.

View Article and Find Full Text PDF
Article Synopsis
  • Fluids in the body shift towards the head during spaceflight, causing internal jugular vein (IJV) swelling and changes in blood flow that may raise thrombosis risk.
  • The study examined how brief weightlessness (0-G) impacts IJV size and blood flow, using ultrasound on 13 participants in different positions on Earth and during spaceflight.
  • Findings showed that while both IJVs enlarge in 0-G, stagnant blood flow was observed in one participant's left IJV, suggesting potential negative effects on venous flow dynamics and increased thromboembolism risk for astronauts during space travel.
View Article and Find Full Text PDF
Article Synopsis
  • The study assessed the impact of two different pneumoperitoneum pressures (standard: 13-15 mmHg and low: 6-8 mmHg) on the internal jugular vein (IJV) cross-sectional area (CSA) during laparoscopic surgeries.
  • Results showed that the CSA of the IJV increased significantly after pneumoperitoneum in both pressure groups, with a larger percentage increase in the standard pressure group compared to the low pressure group.
  • The findings suggest that laparoscopic surgeries can be effectively performed at lower intra-abdominal pressures without compromising safety or surgical feasibility.
View Article and Find Full Text PDF