Background: Work-hour restrictions and fatigue management strategies in surgical training programs continue to evolve in an effort to improve the learning environment and promote safer patient care. In response, training programs must reevaluate how various teaching modalities such as simulation can augment the development of surgical competence in trainees. For surgical simulators to be most useful, it is important to determine whether surgical proficiency can be reliably differentiated using them. To our knowledge, performance on both virtual and benchtop arthroscopy simulators has not been concurrently assessed in the same subjects.
Questions/purposes: (1) Do global rating scales and procedure time differentiate arthroscopic expertise in virtual and benchtop knee models? (2) Can commercially available built-in motion analysis metrics differentiate arthroscopic expertise? (3) How well are performance measures on virtual and benchtop simulators correlated? (4) Are these metrics sensitive enough to differentiate by year of training?
Methods: A cross-sectional study of 19 subjects (four medical students, 12 residents, and three staff) were recruited and divided into 11 novice arthroscopists (student to Postgraduate Year [PGY] 3) and eight proficient arthroscopists (PGY 4 to staff) who completed a diagnostic arthroscopy and loose-body retrieval in both virtual and benchtop knee models. Global rating scales (GRS), procedure times, and motion analysis metrics were used to evaluate performance.
Results: The proficient group scored higher on virtual (14 ± 6 [95% confidence interval {CI}, 10-18] versus 36 ± 5 [95% CI, 32-40], p < 0.001) and benchtop (16 ± 8 [95% CI, 11-21] versus 36 ± 5 [95% CI, 31-40], p < 0.001) GRS scales. The proficient subjects completed nearly all tasks faster than novice subjects, including the virtual scope (579 ±169 [95% CI, 466-692] versus 358 ± 178 [95% CI, 210-507] seconds, p = 0.02) and benchtop knee scope + probe (480 ± 160 [95% CI, 373-588] versus 277 ± 64 [95% CI, 224-330] seconds, p = 0.002). The built-in motion analysis metrics also distinguished novices from proficient arthroscopists using the self-generated virtual loose body retrieval task scores (4 ± 1 [95% CI, 3-5] versus 6 ± 1 [95% CI, 5-7], p = 0.001). GRS scores between virtual and benchtop models were very strongly correlated (ρ = 0.93, p < 0.001). There was strong correlation between year of training and virtual GRS (ρ = 0.8, p < 0.001) and benchtop GRS (ρ = 0.87, p < 0.001) scores.
Conclusions: To our knowledge, this is the first study to evaluate performance on both virtual and benchtop knee simulators. We have shown that subjective GRS scores and objective motion analysis metrics and procedure time are valid measures to distinguish arthroscopic skill on both virtual and benchtop modalities. Performance on both modalities is well correlated. We believe that training on artificial models allows acquisition of skills in a safe environment. Future work should compare different modalities in the efficiency of skill acquisition, retention, and transferability to the operating room.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4773348 | PMC |
http://dx.doi.org/10.1007/s11999-015-4510-8 | DOI Listing |
Orthop Traumatol Surg Res
November 2024
Univ. Rennes, Inserm, LTSI - UMR 1099, F-35000 Rennes, France.
Background: Although virtual reality (VR) simulators have demonstrated their efficiency for basic technical skill training of healthcare professionals, validation for more complex and sequential procedures, especially in arthroscopic surgery, is still warranted. We hypothesized that the VR-based training simulation improves arthroscopic cuff repair skills when transferred to realistic visual and haptic conditions.
Hypothesis: VR-based training simulation improves arthroscopic cuff repair skills when transferred to realistic visual and haptic conditions.
Med Phys
January 2025
Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.
Background: Light-sharing detector designs for positron emission tomography (PET) systems have sparked interest in the scientific community. Particularly, (semi-)monoliths show generally good performance characteristics regarding 2D positioning, energy-, and timing resolution, as well as readout area. This is combined with intrinsic depth-of-interaction (DOI) capability to ensure a homogeneous spatial resolution across the entire field of view (FoV).
View Article and Find Full Text PDFComput Methods Programs Biomed
December 2024
Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA. Electronic address:
Background And Objective: Prosthetic heart valve interventions such as TAVR have surged over the past decade, but the associated complication of long-term, life-threatening thrombotic events continues to undermine patient outcomes. Thus, improving thrombogenic risk analysis of TAVR devices is crucial. In vitro studies for thrombogenicity are typically difficult to perform.
View Article and Find Full Text PDFSci Rep
October 2024
Mechanical Engineering, Vanderbilt University, 2400 Highland Ave, Nashville, 37212, TN, USA.
J Xray Sci Technol
December 2024
Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, China.
Background: The development of photon-counting CT systems has focused on semiconductor detectors like cadmium zinc telluride (CZT) and cadmium telluride (CdTe). However, these detectors face high costs and charge-sharing issues, distorting the energy spectrum. Indirect detection using Yttrium Orthosilicate (YSO) scintillators with silicon photomultiplier (SiPM) offers a cost-effective alternative with high detection efficiency, low dark count rate, and high sensor gain.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!