Overall stent performance should be characterized by geometric luminal gain acquisition, neointimal coverage of the stent struts, and stabilization of the underlying inflammatory neoatheroma. The aim of this study was to compare the performance of zotarolimus-eluting stent (ZES), everolimus-eluting stent (EES) and bare metal stent (BMS) using optical coherence tomography (OCT) and coronary angioscopy. For 36 stented coronary lesions (BMS, 12 lesions; ZES, 11 lesions; EES, 13 lesions) in 27 patients, we calculated neointimal area and uncovered stent strut rate based on OCT findings at 10 months after stent placement. The grades of neointimal coverage and yellow color, both of which were classified from 0 to 3, were also assessed by coronary angioscopy. The plaque area of the ZES lesions was larger than that of the EES lesions (P < 0.05) but smaller than that of the BMS lesions (P < 0.05). The OCT-based uncovered rate of the ZES lesions was less than that of the EES lesions (P < 0.01), but similar to that of the BMS lesions. The stent coverage grade by angioscopy was higher in the ZES lesions than in the EES lesions (P < 0.05), but similar to the BMS lesions. The yellow grade was less in the ZES lesions than in the EES lesions (P < 0.01), but similar to the BMS lesions. ZES might be better than BMS in terms of neointimal thickening, and better than EES in terms of neointimal coverage as well as prevention of neoatheroma formation. ZES may have superior performance compared with EES.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-015-0728-3DOI Listing

Publication Analysis

Top Keywords

coronary angioscopy
12
optical coherence
8
coherence tomography
8
neointimal coverage
8
zes lesions
8
ees lesions
8
stent
7
lesions
6
comparison performance
4
performance zotarolimus-
4

Similar Publications

Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.

View Article and Find Full Text PDF

In this paper, we present the design and fabrication of a novel chip-on-tip catheter, which uses a microcamera and optical fibres to capture in vivo images in a beating porcine heart thanks to a saline flush to clear the blood field. Here, we demonstrate the medical utility and mechanical robustness of this catheter platform system, which could be used for other optical diagnostic techniques, surgical guidance, and clinical navigation. We also discuss some of the challenges and system requirements associated with developing a miniature prototype for such a study and present assembly instructions.

View Article and Find Full Text PDF

This study aimed to explore the impact of cardiac rehabilitation (CR) on in vivo and ex vivo microcirculation, exercise capacity, and oxidative stress in patients with cardiovascular disease (CVD). The study included patients with acute coronary syndrome (ACS; n = 45; age, 69.0 ± 14.

View Article and Find Full Text PDF

Lipid-lowering therapy plays a central role in reducing cardiovascular events. Over the past few decades, clinical trials utilizing several imaging techniques have consistently shown that lipid-lowering therapy can reduce the coronary plaque burden and improve plaque composition. Although intravascular ultrasound has been the most extensively used modality to assess plaque burden, other invasive modalities, such as optical coherence tomography and near-infrared spectroscopy, provide relevant data on plaque vulnerability, and computed tomography angiography detects both plaque volume and characteristics non-invasively.

View Article and Find Full Text PDF