Objective: Most studies on spinal manipulation learning demonstrate the relevance of including motor learning strategies in chiropractic curricula. Two outcomes of practice are the production of movement in an efficient manner and the improved capability of learners to evaluate their own motor performance. The goals of this study were to evaluate if expertise is associated with increased spinal manipulation proficiency and if error detection skills of force application during a high-velocity low-amplitude spinal manipulation are related to expertise.

Methods: Three groups of students and 1 group of expert chiropractors completed 10 thoracic spine manipulations on an instrumented device with the specific goal of reaching a maximum peak force of 300 N after a brief period of practice. After each trial, participants were asked to give an estimate of their maximal peak force. Force-time profiles were analyzed to determine the biomechanical parameters of each participant and the participant's capacity to estimate his or her own performance.

Results: Significant between-group differences were found for each biomechanical parameter. No significant difference was found between groups for the error detection variables (p > .05). The lack of significant effects related to the error detection capabilities with expertise could be related to the specificity of the task and how the training process was structured.

Conclusion: This study confirms that improvements in biomechanical parameters of spinal manipulation are related to expertise. Feedback based on error detection could be implemented in chiropractic curricula to improve trainee abilities in detecting motor execution errors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4770989PMC
http://dx.doi.org/10.7899/JCE-15-4DOI Listing

Publication Analysis

Top Keywords

error detection
20
spinal manipulation
20
detection skills
8
skills force
8
force application
8
manipulation learning
8
chiropractic curricula
8
peak force
8
biomechanical parameters
8
error
5

Similar Publications

Fetal cardiac function in pregnancy affected by congenital heart disease: protocol for a multicentre prospective cohort study.

BMC Pregnancy Childbirth

January 2025

Royal Hospital for Women and UNSW, School of Clinical Medicine, Level 0, Royal Hospital for Women, Barker Street (Locked Bag 2000), Sydney, NSW, 2031, Australia.

Background: Congenital heart disease (CHD) is the most common fetal malformation, and it can result first in cardiac remodeling and dysfunction and later in cardiac failure and hydrops. A limited number of studies have evaluated cardiac function in fetuses affected by CHD. Functional parameters could potentially identify fetuses at risk of cardiac failure before its development.

View Article and Find Full Text PDF

Background: The burden of Clostridioides difficile as a nosocomial- and community-acquired pathogen has been increasing over the recent decades, including reports of severe outbreaks. Molecular and virulence genotyping are central for the epidemiological surveillance of this pathogen, but need to balance accuracy and rapid turnaround time of the results. While Illumina short-read sequencing has been adopted as the gold standard to investigate C.

View Article and Find Full Text PDF

The expansion of LEAN and small batch manufacturing demands flexible automated workstations capable of switching between sorting various wastes over time. To address this challenge, our study is focused on assessing the ability of the Segment Anything Model (SAM) family of deep learning architectures to separate highly variable objects during robotic waste sorting. The proposed two-step procedure for generic versatile visual waste sorting is based on the SAM architectures (original SAM, FastSAM, MobileSAMv2, and EfficientSAM) for waste object extraction from raw images, and the use of classification architecture (MobileNetV2, VGG19, Dense-Net, Squeeze-Net, ResNet, and Inception-v3) for accurate waste sorting.

View Article and Find Full Text PDF

A deep learning based model for diabetic retinopathy grading.

Sci Rep

January 2025

Department of Networks and Cybersecurity, Hourani Center for Applied Scientific Research, Al-Ahliyya Amman University, Amman, Jordan.

Diabetic retinopathy stands as a leading cause of blindness among people. Manual examination of DR images is labor-intensive and prone to error. Existing methods to detect this disease often rely on handcrafted features which limit the adaptability and classification accuracy.

View Article and Find Full Text PDF

Variable power functional dilution adjustment of spot urine.

Sci Rep

January 2025

Praxis Dr.Carmine, Etzelstrasse 21, Pfaeffikon SZ, 8808, Switzerland.

Spot-urinary biomarkers are crucial in medical, epidemiological, and environmental studies, but their variability due to hydration levels requires precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), are limited in compensating for variations in urine concentration, causing substantial inconsistencies, particularly at the extremes of the diuresis spectrum. While restricting the creatinine (CRN) range to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!