The method detection limit (MDL, 99% chance of detecting a positive result in a single replicate), as per the United States Code of Federal Regulations, was determined for a protocol using an ultrafiltration based automated waterborne pathogen concentration device. Bacillus anthracis Sterne strain spores were seeded at low levels into 100 L reagent water samples. Suspect colonies were confirmed through morphological, chemical, and genetic tests. Samples of 100 L (n=14) of reagent water were seeded with five B. anthracis CFUs each. To confirm the estimated detection limit, a second set (n=19) of 100 L reagent water samples were seeded at a higher level (7 CFUs). The second estimate of the MDL could not be pooled with the first, due to significant difference in variance. A third trial (n=7) seeded with 10 CFUs produced an estimate of the MDL that could be pooled with the higher previous estimate. Another trial consisting of eight 100 L samples of tap water were seeded with approximately 7 CFUs. Recovery in these samples was not significantly different from the pooled MDL. Theoretically a concentration of 4.6 spores/100 L would be required for detection 95% of the time, based on a Poisson distribution. The calculated pooled MDL, based on experimental data was approximately 6 B. anthracis CFU/100 L (95% confidence interval 4.8 to 8.4). Detection at this level was achieved in municipal water samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5740/jaoacint.12-461 | DOI Listing |
Vet Parasitol
January 2025
Laboratory of Parasitic Diseases, College of Veterinary Medicine, Shanxi Agricultural University, Taigu, Shanxi Province 030801, PR China. Electronic address:
Toxoplasma gondii, an obligate intracellular protozoan, infects almost all warm-blooded animals and humans, with felines serving as its sole definitive hosts. Cats release T. gondii oocysts into the environment through feces, contributing to environmental contamination that can lead to toxoplasmosis in humans upon exposure through ingestion of contaminated food, water, or soil.
View Article and Find Full Text PDFACS Sens
January 2025
Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, China.
It is crucial yet challenging to sensitively quantify low-abundance biomarkers in blood for early screening and diagnosis of various diseases. Herein, an analytical model of intra-mesopore immunoassay (IMIA) was proposed, which was competent to examine various biomarkers at the femtomolar level. The success is rooted in the design of an innovative superparamagnetic core-shell structure with FeO nanoparticles (NPs) at the core and hierarchically porous zeolitic imidazolate frameworks as a shell (FeO@HPZIF-8), achieved through a soft-template directed self-assembly coupled with confinement growth mechanism.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jianghan University, Wuhan, 430056, China.
An electrochemical sensor is presented for the detection of the chloramphenicol (CAP) based on a bimetallic MIL-101(Fe/Co) MOF electrocatalyst. The MIL-101(Fe/Co) was prepared by utilizing mixed-valence Fe (III) and Co (II) as metal nodes and terephthalic acid as ligands with a simple hydrothermal method and characterized by SEM, TEM, XRD, FTIR, and XPS. Electrochemical measurements such as electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and differential pulse voltammetry (DPV) showed that bimetallic MIL-101(Fe/Co) had the faster electron transfer, larger electroactive area, and higher electrocatalytic activity compared with their monometallic counterparts due to the strong synergistic effect between bimetals.
View Article and Find Full Text PDFAnal Chem
January 2025
College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
The detection of disease-related protein biomarkers plays a crucial role in the early diagnosis, treatment, and monitoring of diseases. The concentrations of protein biomarkers can vary significantly in different diseases or stages of the same disease. However, most of the existing analytical methods cannot simultaneously meet the requirements of high sensitivity and a wide dynamic range.
View Article and Find Full Text PDFSmall
January 2025
Institute of Biomass and Function Materials & National Demonstration Centre for Experimental Light Chemistry Engineering Education, College of Bioresources Chemistry and Materials Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, P. R. China.
As skin bioelectronics advances, hydrogel wearable devices have broadened perspectives in environment sensing and health monitoring. However, their application is severely hampered by poor mechanical and self-healing properties, environmental sensitivity, and limited sensory functions. Herein, inspired by the hierarchical structure and unique cross-linking mechanism of hagfish slime, a self-powered supramolecular hydrogel is hereby reported, featuring high stretchability (>2800% strain), ultrafast autonomous self-healing capabilities (electrical healing time: 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!