A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On the validity of the (13) C-acetate breath test for comparing gastric emptying of different liquid test meals: a validation study using magnetic resonance imaging. | LitMetric

Background: (13) C-acetate breath testing (BT) is applied to assess and compare gastric emptying of liquid meals. Gastric half-emptying times (t50 ) from BT show offsets compared to t50 values from γ-scintigraphy and ultrasonography. Linear transformations have been proposed to correct these offsets. This investigation critically validates the BT for the assessment of liquid gastric emptying by using simultaneously recorded meal and total gastric content volume emptying data from magnetic resonance imaging (MRI).

Methods: Data were collected during a recently published double-blind, randomized, cross-over MRI gastric emptying study of three (13) C-labeled enteral formulas differing in protein sources (PMID: 24699556). Breath testing-derived t50 was computed with the analysis methods commonly applied in gastric emptying research, i.e., the exponential-beta function and the Wagner-Nelson (WN) method, respectively.

Key Results: Breath testing t50 values from exponential-beta function and WN method showed a positive and negative offset to MRI data, respectively. Linear regression detected low concordance between MRI and both BT methods revealing meal specific and emptying rate-dependent offsets. The WN method showed worse agreement and correlation with MRI emptying data. Breath testing rather reflected meal volume than total gastric content volume emptying.

Conclusions & Inferences: This validation study indicates that the (13) C-acetate breath test may not be applied to compare gastric emptying of arbitrary liquid meals without prior validation by imaging methods. t50 values from BT are biased by (i) the properties of the meal and (ii) the selected method used for (13) CO2 exhalation analysis. No linear transformation common for all meals was applicable to correct the offsets between BT and MRI.

Download full-text PDF

Source
http://dx.doi.org/10.1111/nmo.12648DOI Listing

Publication Analysis

Top Keywords

gastric emptying
24
c-acetate breath
12
breath testing
12
t50 values
12
gastric
9
emptying
9
breath test
8
emptying liquid
8
validation study
8
magnetic resonance
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!