A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft. | LitMetric

Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft.

Int Orthop

Department of Orthopaedic Surgery, College of Medicine, Daejeon St. Mary's Hospital, The Catholic University of Korea, Daeheung-ro 64, Jung-gu, Daejeon, 301-723, Republic of Korea.

Published: March 2016

Purpose: To evaluate the clinical and radiological outcomes of unstable proximal humeral fractures (PHFs) treated with a locking plate and fibular strut allograft.

Methods: This study included 36 patients [7 men, 29 women; mean age, 68 years (range, 22-94 years)] with unstable PHFs with medial column disruption. All patients were treated with open reduction and internal fixation using a locking plate and fibular strut allograft. Post-operative assessment included clinical outcomes, shoulder range of motion, radiographic examination, and any complications. Post-operative radiological assessment including the humerus neck-shaft angle (NSA) and the humeral head height was performed.

Results: At the mean two year follow-up visit, the mean American Shoulder and Elbow Society (ASES) and University of California, Los Angeles (UCLA) scores were 77 and 28, respectively. According to the UCLA rating scale, the result was excellent in six, good in 20, fair in six, and poor in four cases. According to the Paavolainen method, 31 patients had good results with an NSA of 130 ± 10°; three patients showed fair results with an NSA of 100-120°, and two patients experienced a poor result with an NSA of <100°. When calculating the humeral head height, the mean loss of reduction was measured as 1.6 mm (from 10.8 or 9.2 mm). Varus collapse and avascular necrosis of the humeral head was noted in two patients for each condition.

Conclusions: For unstable proximal humerus fractures, particularly in elderly patients with severe osteoporosis or in younger patients with a four-part fracture, locking plate fixation with a fibular strut allograft provided rigid medial support and showed satisfactory clinical and radiological outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-015-2950-0DOI Listing

Publication Analysis

Top Keywords

locking plate
12
plate fibular
12
fibular strut
12
clinical radiological
8
radiological outcomes
8
outcomes unstable
8
unstable proximal
8
proximal humeral
8
humeral fractures
8
treated locking
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!