Objectives: We sought to identify if baseline characteristic differences in patients who receive a 23 mm vs. 26 mm valve impact clinical outcomes.
Background: Transcatheter aortic valve replacement (TAVR) is currently an approved therapy for patients with severe aortic stenosis who are considered inoperable or are at high risk.
Methods: We retrospectively examined baseline characteristics and outcomes of patients receiving a 23 mm (n = 132) vs. 26 mm valve (n = 81) via the transfemoral approach.
Results: Gender (P < 0.01), previous coronary artery bypass surgery (P < 0.01), history of atrial fibrillation (P = 0.04), and mean Society of Thoracic Surgeons (STS) score (P < 0.01) were significantly different between groups. There were no significant differences in the rates of minor/major vascular complications (2.2 vs. 3.7%, P = 0.68 and 13.0 vs. 12.3%, P = 0.89, respectively). Bleeding complications were also comparable (major bleed 2.3 vs. 1%, P >0.99, minor bleed 19.0 vs. 22.0%, P = 0.67 and life threatening bleed 7.0 vs. 5.0%, P = 0.77). In-hospital death (6.0 vs. 5.0%, P >0.99), 30-day all-cause death (7.6 vs. 6.2%, P = 0.69), and all-cause death at 1 year (17.4 vs. 25.9%, P = 0.13) were also similar between groups. Gender, valve size, previous coronary bypass surgery and atrial fibrillation were not independently associated with mortality; however, on multivariate analysis STS score was (HR 1.11; 95% CI 1.02-1.19; P = 0.01).
Conclusion: Patients undergoing TAVR with 23 and 26 mm valves have similar clinical outcomes despite significant differences in baseline characteristics. © 2015 Wiley Periodicals, Inc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.25967 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!