Suture retention strength (SRS) is commonly used as a measure the ability of sutures to adhere implants to surrounding tissue. While SRS is widely employed, surprisingly its effects on graft microstructure have not been characterized. This is particularly germane to the broad utilization of electrospun implants in tissue engineering. These implants need to retain their initial nanoscale topography while simultaneously preserving clinically critical mechanical properties. We examined the suture-driven microstructural deformation of polycaprolactone electrospun to form both square and tubular SRS samples. The impact of fiber orientation (generally parallel or random orientation, orthogonally aligned) on the SRS of these vascular tissue equivalents was analyzed and compared to native and decellularized porcine vasculature. The initial state of the fiber clearly dictates the overall efficiency of scaffold utilization. SRS values for as-spun fibers at a thickness of 300 μm were found to be in the range of 1.59-4.78 N for the three orientations. Unexpectedly, random fibers provided the optimal SRS values based on both resistance to suture motion and the percentage of scaffold involvement. A "V-shaped" failure morphology is observed for both electrospun scaffolds and native tissue during SRS testing. Post-test fiber alignment in the tensile direction was visible in all initial fiber orientations similar to that of native tissue. These findings are significant as they allow us to employ new, counterintuitive biomimetic design criteria for nanofiber-based scaffolds in which reliable mechanical integration with the surrounding tissues via suture-based methods is important. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1525-1534, 2016.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.33493DOI Listing

Publication Analysis

Top Keywords

suture retention
8
retention strength
8
tissue srs
8
srs values
8
native tissue
8
srs
7
tissue
5
biomimetic microstructural
4
microstructural reorganization
4
reorganization suture
4

Similar Publications

Purpose: To assess the variability in graft biomechanical properties of an acellular human dermal matrix patch.

Methods: A total of 22 strips obtained from 6 separate graft specimens (AlloPatch HD) were tested. Load elongation properties after cyclic loading, including ultimate load at break, energy at break, and extension at break, were tested and compared by graft thickness.

View Article and Find Full Text PDF

Background/objectives: This study was conducted to compare two modes of computed tomography fluoroscopy (CTF) and two gastropexy techniques used in CT-guided percutaneous radiologic gastrostomy (CT-PRG) aiming to identify the optimal techniques for image guidance and gastropexy and, thus, to overcome the current lack of consensus on the preferred modalities.

Methods: We retrospectively identified 186 successful CT-PRG procedures conducted evenly across two university hospitals from January 2019 to December 2023. Patients were divided into two groups (intermittent multislice CT biopsy mode-guided technique (MS-CT BM) and retention anchor suture (T-fastener) versus real-time (RT-)CTF and gastropexy device) for descriptive analysis of demographics, indication for PRG, radiation exposure (DLP), procedural time, number of CT scans, gastropexy time, and complications.

View Article and Find Full Text PDF

Background: During the modified Broström procedure for chronic ankle instability, surgeons often experience cases with insufficiently restored mechanical stability even after anatomical ligament repair. In these cases, longer postoperative immobilization and delayed rehabilitation can be required, and a risk for recurrence of instability may persist. This study aimed to evaluate the clinical usefulness of suture-tape augmentation based on intraoperative stress radiographs during anatomical ligament repair for chronic ankle instability.

View Article and Find Full Text PDF

Postoperative Sinus Tract: A Rare Occurrence Following Laparoscopic Cholecystectomy.

Cureus

October 2024

Department of General Surgery, Dr. D.Y. Patil Medical College, Hospital and Research Centre, Dr. D.Y. Patil Vidyapeeth (Deemed to be University), Pune, IND.

A sinus tract is a rare clinical condition characterized by a blind-ended tubular structure extending from deeper tissues to the skin, commonly occurring postoperatively, especially after gastrointestinal surgeries. Its pathogenesis often involves the breakdown of fatty tissue, pyogenic infections, or the retention of foreign bodies such as surgical implants or sutures. One notable scenario includes sinus tract formation following laparoscopic cholecystectomy due to retained gallstones.

View Article and Find Full Text PDF

Porous photo-crosslinked hybrid networks based on poly(trimethylene carbonate-co-ε-caprolactone) and recombinant human-like collagen.

Biomater Adv

February 2025

Advanced Organ bioengineering and Therapeutics, Department of Bioengineering Technologies, Faculty of Science and Technology, TechMed Centre, University of Twente, Drienerlolaan 5, 7522, NB, Enschede, the Netherlands.

Hybrid hydrogel networks were prepared from recombinant human-like collagen (rh-collagen) and poly(trimethylene carbonate-co-ε-caprolactone) (P (TMC-co-ε-CL)) to overcome the mechanical and bioactivity limitations associated with the respective individual networks. Both polymers were functionalised with methacrylic anhydride to yield photo-crosslinkable materials. Porous hybrid networks of different compositions were prepared by photo-crosslinking frozen mixtures of solutions of the functionalized polymers in acidified DMSO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!