Purpose: To determine biomechanical differences between a fixed-angle locking volar titanium plate (VariAx; Stryker, Kalamazoo, MI) and a fixed-angle compression locking volar stainless steel plate (CoverLoc Volar Plate; Tornier, Amsterdam, Netherlands) in the fixation of simulated AO C3 distal radius fractures.

Methods: Eighteen cadaveric upper extremities (9 matched pairs) with an average age of 54 years were tested. A 4-part AO C3 fracture pattern was created in each specimen. The fractures were reduced under direct vision and fixed with either the fixed-angle locking volar titanium plate or the fixed-angle compression locking volar stainless steel plate. Motion tracking analysis was then performed while the specimens underwent cyclic loading. Changes in displacement, rotation, load to failure, and mode of failure were recorded.

Results: The fragments, when secured with the fixed-angle compression locking stainless steel construct, demonstrated less displacement and rotation than the fragments secured with the fixed-angle locking titanium plate under physiological loading conditions. In the fixed-angle compression locking stainless steel group, aggregate displacement and rotation of fracture fragments were 5 mm and 3° less, respectively, than those for the fixed-angle locking titanium group. The differences between axial loads at mechanical failure and stiffness were not statistically significant. The compression locking stainless steel group showed no trend in mode of failure, and the locking titanium plate group failed most often by articular fixation failure (5 of 9 specimens).

Conclusions: The fixed-angle compression locking stainless steel volar plate may result in less displacement and rotation of fracture fragments in the fixation of AO C3 distal radius fractures than fixation by the fixed-angle locking volar titanium plate. However, there were no differences between the plates in mechanical load to failure and stiffness.

Clinical Relevance: Fixation of distal radius AO C3 fracture patterns with the fixed-angle compression locking stainless steel plate may provide improved stability of fracture fragments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2015.06.098DOI Listing

Publication Analysis

Top Keywords

stainless steel
32
compression locking
28
fixed-angle locking
24
fixed-angle compression
24
locking volar
20
titanium plate
20
locking stainless
20
distal radius
16
displacement rotation
16
locking
14

Similar Publications

Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.

Settings And Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.

Materials And Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone.

View Article and Find Full Text PDF

On the analysis of adapting deep learning methods to hyperspectral imaging. Use case for WEEE recycling and dataset.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

TECNALIA, Basque Research and Technology Alliance (BRTA), Parque Tecnológico de Bizkaia, C/ Geldo. Edificio 700, E-48160, Derio - Bizkaia, Spain; University of the Basque Country, Plaza Torres Quevedo, 48013 Bilbao, Spain.

Hyperspectral imaging, a rapidly evolving field, has witnessed the ascendancy of deep learning techniques, supplanting classical feature extraction and classification methods in various applications. However, many researchers employ arbitrary architectures for hyperspectral image processing, often without rigorous analysis of the interplay between spectral and spatial information. This oversight neglects the implications of combining these two modalities on model performance, consumption, and inference time.

View Article and Find Full Text PDF

A previous companion paper introduced a current pathways model that represents the electrical coupling between the Hall effect thruster (HET) and the ground-based vacuum test facility operational environment. In this work, we operated a 7-kW class HET at 4.5 kW, 15 A and 6 kW, 20 A on krypton to quantify aspects of the current pathways model to characterize the role metal vacuum chambers play in the thruster's discharge circuit as a function of discharge current.

View Article and Find Full Text PDF

Multifunctional ortho-quinones are required for the formation of thiol-catechol-connectivities (TCC) but can be delicate to handle. We present the electrochemical oxidation of the dipeptide DiDOPA, achieving up to 92% conversion efficiency of the catechols to ortho-quinones. Graphite and stainless steel could be employed as cost-efficient electrodes.

View Article and Find Full Text PDF

Objective: This study aims to compare the impact of titanium and stainless steel (SS) retainer wires on lower incisor stability and periodontal health.

Methods: Fifty patients between the ages of 14.1 and 29.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!