The reliability of Fricke gel dosimeters in form of layers for measurements aimed at the characterization of epithermal neutron beams has been studied. By means of dosimeters of different isotopic composition (standard, containing (10)B or prepared with heavy water) placed against the collimator exit, the spatial distribution of gamma and fast neutron doses and of thermal neutron fluence are attained. In order to investigate the accuracy of the results obtained with in-air measurements, suitable MC simulations have been developed and experimental measurements have been performed utilizing Fricke gel dosimeters, thermoluminescence detectors and activation foils. The studies were related to the epithermal beam designed for BNCT irradiations at the research reactor LVR-15 (Řež). The results of calculation and measurements have revealed good consistency of gamma dose and fast neutron 2D distributions obtained with gel dosimeters in form of layers. In contrast, noticeable modification of thermal neutron fluence is caused by the neutron moderation produced by the dosimeter material. Fricke gel dosimeters in thin cylinders, with diameter not greater than 3mm, have proved to give good results for thermal neutron profiling. For greater accuracy of all results, a better knowledge of the dependence of gel dosimeter sensitivity on radiation LET is needed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2015.07.036DOI Listing

Publication Analysis

Top Keywords

gel dosimeters
16
fricke gel
12
thermal neutron
12
in-air measurements
8
neutron
8
neutron beams
8
dosimeters form
8
form layers
8
fast neutron
8
neutron fluence
8

Similar Publications

A gamma cell unit is used for gamma irradiation of small volume samples. Due to the sample volume, there is a dose distribution, which is imperative to be known for appropriate irradiation. In this study, samples of agarose Fricke gel dosimeters were prepared for the dose mapping of the gamma cell unit available in our laboratory.

View Article and Find Full Text PDF

Background And Purpose: During an end-to-end (E2E) test on the online workflow of the MR-linac, the performance of the treatment starting from the acquisition of pre-treatment MRI scans and ending with dose delivery is quantified. In such a test, the geometrical accuracy of the entire workflow is assessed. Ideally, the 3D geometrical accuracy of dose delivery on an MR-linac should be assessed using dosimeters that provide 3D dose distributions.

View Article and Find Full Text PDF

Background: Comprehensive quality assurance (QA) for a seamless workflow of high-dose-rate brachytherapy, from imaging to planning and irradiation, is uncommon, and QA of the source dwell position is performed in one- or two-dimensions. Gel dosimetry using magnetic resonance imaging (MRI) is effective in verifying the three-dimensional distribution of doses for image-guided brachytherapy (IGBT). However, MRI scanners are not readily accessible, and MRI scanning is time-consuming.

View Article and Find Full Text PDF

Quantitative spatial visualization of X-ray irradiation via redox reaction by dynamic nuclear polarization magnetic resonance imaging.

Free Radic Biol Med

November 2024

Department of Radiology, Gifu University, Gifu, Japan; Innovation Research Center for Quantum Medicine, Gifu University, Gifu, Japan; Department of Radiology, Frontier Science for Imaging, School of Medicine, Gifu University, Gifu, Japan.

The dose of X-ray irradiation is commonly measured by point assessment with an ionization chamber dosimeter. However, to achieve spatially accurate delivery of X-ray to avoid the exposure to normal tissues, an accurate imaging method for spatially and quantitatively detecting exposure is required. Herein, we present a novel method to visualize X-ray exposure using low-field dynamic nuclear polarization magnetic resonance imaging (DNP-MRI) with nitroxyl radical tempol as the chemical dosimeter.

View Article and Find Full Text PDF
Article Synopsis
  • This study focuses on using a surfactant hydrogel dosimeter (SHD) to accurately measure 3D absorbed dose distributions in carbon ion radiotherapy, which is important for targeting tumors effectively.
  • The researchers set up a cubic target region and conducted carbon ion beam irradiation, measuring the response of the SHD using optical computed tomography to gather data about the absorbed dose.
  • Results showed that the optical attenuation coefficients (OAC) measured were lower than the expected absorbed dose, indicating discrepancies that may affect precise dosimetry in treatment planning.
View Article and Find Full Text PDF