The purpose of this study is to develop nuclear-Overhauser-enhanced (NOE) [(1)H]-(31)P magnetic resonance imaging (MRI) based on 3D fully-balanced steady-state free precession (fbSSFP). Therefore, two implementations of a 3D fbSSFP sequence are compared using frequency-selective excitation (FreqSel) and multipoint-Dixon (MP-Dixon). (31)P-containing model solutions and four healthy volunteers were examined at field strengths of B0=3T and 7T. Maps of the distribution of phosphocreatine (PCr), inorganic phosphate (Pi), and adenosine 5´-triphosphate (ATP) in the human calf were obtained with an isotropic resolution of 1.5cm (1.0cm) in an acquisition time of 5min (10min). NOE-pulses had the highest impact on the PCr acquisitions enhancing the signal up to (82 ± 13) % at 3T and up to (37 ± 9) % at 7T. An estimation of the level of PCr in muscle tissue from [(1)H]-(31)P MRI data yielded a mean value of (33 ± 8) mM. In conclusion, direct [(1)H]-(31)P imaging using FreqSel as well as MP-Dixon is possible in clinically feasible acquisition times. FreqSel should be preferred for measurements where only a single metabolite resonance is considered. MP-Dixon performs better in terms of SNR if a larger spectral width is of interest.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2015.07.017DOI Listing

Publication Analysis

Top Keywords

frequency-selective excitation
8
nuclear-overhauser-enhanced imaging
4
imaging 31p-containing
4
31p-containing metabolites
4
metabolites multipoint-dixon
4
multipoint-dixon frequency-selective
4
excitation purpose
4
purpose study
4
study develop
4
develop nuclear-overhauser-enhanced
4

Similar Publications

Homonuclear J-couplings and heteronuclear structural constraints.

J Magn Reson

November 2024

Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States. Electronic address:

In magic angle spinning (MAS) experiments involving uniformly C/N labeled proteins, C-C and C-N dipolar recoupling experiments are now routinely used to measure direct dipole-dipole couplings that constrain distances and torsion angles and determine molecular structures. When the distances are short (<4 Å), the direct couplings dominate the evolution of the spin system, and the C-C and C-N J-couplings (scalar couplings) are ignored. However, for structurally interesting >4 Å distances, the dipolar and J-couplings are generally of comparable magnitude, and the variation in J must be included in order to optimize the precision of the experiment.

View Article and Find Full Text PDF

Three-dimensional (3D) projection acquisition (PA) imaging has recently gained attention because of its advantages, such as achievability of very short echo time, less sensitivity to motion, and undersampled acquisition of projections without sacrificing spatial resolution. However, larger subjects require a stronger Nyquist criterion and are more likely to be affected by outer-volume signals outside the field of view (FOV), which significantly degrades the image quality. Here, we proposed a variable slab-selective projection acquisition (VSS-PA) method to mitigate the Nyquist criterion and effectively suppress aliasing streak artifacts in 3D PA imaging.

View Article and Find Full Text PDF

We aim to automatize the identification of collective variables to simplify and speed up enhanced sampling simulations of conformational dynamics in biomolecules. We focus on anharmonic low-frequency vibrations that exhibit fluctuations on time scales faster than conformational transitions but describe a path of least resistance toward structural change. A key challenge is that harmonic approximations are ill-suited to characterize these vibrations, which are observed at far-infrared frequencies and are easily excited by thermal collisions at room temperature.

View Article and Find Full Text PDF

Achieving high-resolution and high signal-to-noise ratio (SNR) in vivo metabolic imaging via fast magnetic resonance spectroscopic imaging (MRSI) has been a longstanding challenge. This study combines the methods of relaxation enhancement (RE) and subspace imaging for the first time, enabling high-resolution and high-SNR in vivo MRSI of rodent brains at 9.4 T.

View Article and Find Full Text PDF

The Impact of the Fluid-Solid Coupling Behavior of Macro and Microstructures in the Spiral Cochlea on Hearing.

J Biomech Eng

June 2024

School of Mechanics and Engineering Science, Shanghai Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai 200072, China.

The cilia of the outer hair cells (OHCs) are the key microstructures involved in cochlear acoustic function, and their interactions with lymph in the cochlea involve complex, highly nonlinear, coupled motion and energy conversions, including macroscopic fluid-solid coupling. Recent optical measurements have shown that the frequency selectivity of the cochlea at high sound levels is entirely mechanical and is determined by the interactions of the hair bundles with the surrounding fluid. In this paper, an analytical mathematical model of the spiral cochlea containing macro- and micromeasurements was developed to investigate how the phonosensitive function of OHCs' motions is influenced by the macrostructural and microstructural fluid-solid coupling in the spiral cochlea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!