In this work, a highly reproducible standard gas generating vial is proposed. The vial is comprised of a silicon diffusion pump oil spiked with an appropriate calibration compound, such as modified McReynolds probes (benzene, 2-pentanone, pyridine, 1-nitropropane, 1-pentanol, and n-octane), and then mixed with polystyrene/divinylbenzene (PS/DVB) particles. The concentrations of these compounds in gaseous headspace were found to substantially decrease in comparison to previously developed hydrocarbon pump oil based vials; hence, the amount of standard loaded onto SPME fibers was at most, half that of the previous vial design. Depletion for all compounds after 208 successive extractions was shown to be less than 3.5%. Smaller quantities of standards being used resulted in a vial that depleted slower while remaining statistically repeatable over a wider number of runs. Indeed, it was found that depletion could be largely predicted by using a mass balance theoretical model. This behavior allowed a further increase in the number of loadings that could be performed repeatedly. At a 95% level of confidence, the ANOVA test demonstrated that the prepared vials were statistically identical, with no significant intra- or inter-batch differences. In addition, it was found that vials stored under different conditions (e.g. under light exposure, room temperature, and within a refrigerator) were stable over 10 weeks. Silicon based vials proved to be ideal for performing instrument quality control and loading of internal standards onto fibers, both of which are of great importance when performing on-site analysis using portable GC-MS instrumentation and high throughput determinations in laboratory.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2015.07.063 | DOI Listing |
Sci Rep
December 2024
Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Bisphenol A (BPA) is a chemical produced in large quantities for use primarily in the production of polycarbonate plastics, which has risks for human health. This study aimed to investigate BPA contents in canned fruit and vegetable samples using Gas Chromatography-Mass Spectrometry (GC-MS). Furthermore, health risks were assessed for Iranian adults and children using Monte Carlo simulations.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Agricultural Entomology, Tamil Nadu Agricultural University, Coimbatore, 641003, India.
An efficient modified QuEChERS procedure was established for the simultaneous determination of 37 pesticide residues in fresh and processed edible button mushroom by employing GC/ GC-MS and LC-MS/MS. The effectiveness, reliability and accuracy of the method were assessed through validation parameters such as linearity, LOD, LOQ, precision, accuracy, uncertainty, and matrix effect. The linearity calibration for all the selected pesticides at standard concentrations (0.
View Article and Find Full Text PDFJ Chromatogr A
December 2024
School of Chemical Engineering, Guizhou Minzu University, Guiyang, China. Electronic address:
This paper reports a method for determining the carbonation rate (CR) of precipitated calcium carbonate (PCC) during carbonation process based on headspace gas chromatography technique. The method was carried out by simultaneously detecting the signal values of carbon dioxide and oxygen. Then the carbonation rate of precipitated calcium carbonate in the carbonation process can be calculated by the ratio (γ) of carbon dioxide to oxygen based on a new mathematical model.
View Article and Find Full Text PDFJ Funct Biomater
December 2024
CS-Surgical Sciences and Technologies-SS Omics Science Platform for Personalized Orthopedics, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
Magnesium and its alloys represent promising candidates for biomedical implants due to their biodegradability and mechanical properties, which are similar to natural bone. However, their rapid degradation process characterized by dynamic pH fluctuations and significant hydrogen gas evolution during biocorrosion adversely affects both in vitro and in vivo assessments. While the ISO 10993-5 and 12 standards provide guidelines for evaluating the in vitro biocompatibility of biodegradable materials, they also introduce testing variability conditions that yield inconsistent results.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
Department of Operative Dentistry, Aichi Gakuin School of Dentistry, Nagoya 464-8651, Japan.
Universal shade flowable composites have been introduced to mimic tooth structure with reduced color mismatch and reduced chair time and cost. However, the polymerization shrinkage of resin material may lead to sensitivity and restoration failure. The purpose of this study was to compare the polymerization shrinkage of recently introduced universal shade flowable resin-based composites using both wet and dry density methods.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!