The 10 Hounsfield units unenhanced computed tomography attenuation threshold does not apply to cortisol secreting adrenocortical adenomas.

Eur J Endocrinol

Department of EndocrinologyReferral Center for Rare Adrenal Diseases, Cochin Hospital, Assistance Publique Hôpitaux de Paris, Université Paris Descartes, Sorbonne Paris Cité, 27, rue du Faubourg Saint Jacques, 75014 Paris, FranceDepartment of EndocrinologyDiabetes Mellitus, and Metabolic Diseases, Avicenne Hospital, Assistance Publique Hôpitaux de Paris, Paris XIII University, 93009 Bobigny, FranceMetabolic UnitWestern General Hospital, Edinburgh, UKDepartment of RadiologyAssistance Publique Hôpitaux de Paris, Hôpital Cochin, Paris, FranceUniversité Paris DescartesSorbonne Paris Cité, Paris, FranceDepartment of Digestive and Endocrine SurgeryHormonal BiologyAssistance Publique Hôpitaux de Paris, Hôpital Cochin, Paris, FranceDepartment of PathologyAssistance Publique Hôpitaux de Paris, Hôpital Pitié-Salpétrière, Pierre et Marie Curie Université, Paris, FranceDepartment of PathologyAssistance Publique Hôpitaux de Paris, Hôpital Cochin, Paris, FranceINSERM U1016CNRS UMR8104, Institut Cochin, Paris, France Department of EndocrinologyReferral Center for Rare Adrenal Diseases, Cochin Hospital, Assistance Publique Hôpitaux de Paris, Université Paris Descartes, Sorbonne Paris Cité, 27, rue du Faubourg Saint Jacques, 75014 Paris, FranceDepartment of EndocrinologyDiabetes Mellitus, and Metabolic Diseases, Avicenne Hospital, Assistance Publique Hôpitaux de Paris, Paris XIII University, 93009 Bobigny, FranceMetabolic UnitWestern General Hospital, Edinburgh, UKDepartment of RadiologyAssistance Publique Hôpitaux de Paris, Hôpital Cochin, Paris, FranceUniversité Paris DescartesSorbonne Paris Cité, Paris, FranceDepartment of Digestive and Endocrine SurgeryHormonal BiologyAssistance Publique Hôpitaux de Paris, Hôpital Cochin, Paris, FranceDepartment of PathologyAssistance Publique Hôpitaux de Paris, Hôpital Pitié-Salpétrière, Pierre et Marie Curie Université, Paris, FranceDepartment of PathologyAssistance Publique Hôpitaux de Paris, Hôpital Cochin

Published: September 2015

Context: Computed tomography (CT) unenhanced attenuation value of <10 Hounsfield units (HU) has an excellent specificity (98%) to diagnose lipid-rich adrenocortical adenomas (ACAs) with a weaker sensitivity (71%).

Objective: To determine from a routine clinical perspective if unenhanced attenuation value is influenced by cortisol secretion in ACAs.

Design: This was a retrospective study of cases collected between 2009 and 2012.

Setting: This study was conducted in a tertiary-care university hospital.

Patients: Seventy-two patients operated on for an ACA (Weiss score ≤ 2) were analysed. Thirty-four patients had an ACA oversecreting cortisol (Cush-ACA). Thirty-eight patients had an ACA without cortisol oversecretion (Non Hyper-ACA).

Main Outcome Measure: CT unenhanced attenuation value was correlated with the functional status. The Weiss score items were analysed.

Results: Among the 34 patients with a Cush-ACA a minority (n = 7) had an unenhanced attenuation value under 10 HU. Among the high precontrast density (> 10 HU) Cush-ACAs, washout analysis after contrast administration was consistent with the benign nature of the tumor in ∼ 60% of the cases. Less than 25% clear cells (lipid-rich cells), a Weiss score item, was present in 50% of the Cush-ACAs in favour of a lipid-poor content.

Conclusions: Unenhanced attenuation value has a poor sensitivity to diagnose an ACA in case of cortisol oversecretion due to poor lipid content. Nevertheless, the accuracy of washout analysis was preserved in the group of Cush-ACAs.

Download full-text PDF

Source
http://dx.doi.org/10.1530/EJE-15-0036DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
unenhanced attenuation
8
washout analysis
8
hounsfield units
4
units unenhanced
4
unenhanced computed
4
tomography attenuation
4
attenuation threshold
4
threshold apply
4
apply cortisol
4

Similar Publications

Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.

View Article and Find Full Text PDF

Objective: To investigate differences in arterial involvement patterns on F-FDG PET-CT between predominant cranial and isolated extracranial phenotypes of giant cell arteritis (GCA).

Methods: A retrospective review of F-FDG PET-CT findings was conducted on 140 patients with confirmed GCA. The patients were divided into two groups: the cranial group, which presented craniofacial ischemic symptoms either at diagnosis or during follow-up, and the isolated extracranial group which never exhibited such manifestations.

View Article and Find Full Text PDF

Early Lung Adenocarcinoma Manifesting as Irregular Subsolid Nodules: Clinical and CT Characteristics.

Acad Radiol

December 2024

Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China (P.-l.Z., T.-y.L., F.-j.L., Q.L.). Electronic address:

Rationale And Objectives: To explore the clinical and computed tomography (CT) characteristics of early-stage lung adenocarcinoma (LADC) that presents with an irregular shape.

Materials And Methods: The CT data of 575 patients with stage IA LADC and 295 with persistent inflammatory lesion (PIL) manifesting as subsolid nodules (SSNs) were analyzed retrospectively. Among these patients, we selected 233 patients with LADC and 140 patients with PIL, who showed irregular SSNs, hereinafter referred to as irregular LADC (I-LADC) and irregular PIL (I-PIL), respectively.

View Article and Find Full Text PDF

Background: Multidose iodinated contrast media (ICM) injectors have shown promise in reducing ICM waste. This study aims to evaluate the impact of patient volume on ICM waste reduction in multidose injectors.

Methods: CT studies performed over one-year period with a multidose injector at our emergency CT unit.

View Article and Find Full Text PDF

A Double-Blind Randomized Crossover Trial Comparing the Esthetic Outcomes Of CAD-CAM Provisional Restorations Fabricated Using CBCT And IOS Acquisition Methods.

J Dent

December 2024

Professor and Clinic director, Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich Switzerland. Electronic address:

Objectives: This double-blind randomised crossover trial aimed to compare the aesthetic outcomes of CAD-CAM manufactured provisional restorations created using cone beam computed tomography (CBCT) and intraoral scanners (IOS) acquisition methods.

Methods: Twelve participants (mean-age: 38 ± 5 years) requiring full mouth rehabilitation were included in this crossover trial. Two sets of identical CAD-CAM provisional restorations, differing only in the method of data acquisition (A: CBCT, B: IOS), were fabricated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!