A simple, accurate and reproducible reversed-phase liquid chromatographic method was developed for qualitative and quantitative determination of four bioactive flavonoids (ampelopsin, taxifolin, myricetin and quercetin) from the fruit-stalk extract of Hovenia dulcis Thunb. Chromatographic separation was performed on a C18 column (4.6 × 150 mm, 3.5 µm) with mobile phase consisting of 0.1% acetic acid and 100% acetonitrile at a flow rate of 1.0 mL/min. The analysis was performed using a diode array detector at 365 nm. The method was validated in terms of selectivity, linearity, accuracy, precision and recovery. Good linearity was observed over the investigated concentration range (10-500 μg/mL), with correlation coefficient values greater than 0.99. The intra- and inter-day precisions over the concentration range were <3.91% (relative standard deviation), and the accuracy was between 91.57 and 106.66%. The mean recovery for all the analytes was 100.87%. This method was successfully applied in the quality assessment of bioactive flavonoids in the fruit-stalk extract of H. dulcis.