A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Two-year Randomized, Controlled Clinical Trial of a Flowable and Conventional Composite in Class I Restorations. | LitMetric

Objectives: This study evaluated the two-year clinical performance and volumetric wear of a flowable resin composite compared to a conventional highly filled composite resin in Class I restorations.

Methods And Materials: In this single-center, single-blinded, comparator-controlled clinical study (Institutional Review Board approved), 120 carious teeth distributed in 60 patients were randomly assigned to four calibrated practitioners who placed occlusal restorations (n=60 flowable and n=60 conventional composite). Direct and indirect assessment at baseline, six months, one year, and two years occurred during which the modified Cvar and Ryge criteria were evaluated. Volumetric wear was determined by superimposition of profilometer scans of baseline and two-year casts.

Results: At two years, there was no significant difference in anatomic form (p=0.80), color match (p=0.08), marginal adaptation (p=0.89), marginal discoloration (p=0.79), surface integrity (p=0.18), secondary caries (p=0.66), cold sensitivity (p=0.522), occlusal sensitivity (p=0.818), or volumetric wear (p=0.661) between materials. Both materials showed a decrease in all criteria except secondary caries (p=0.95) over time. Two-year mean volumetric wear was 3.16 ± 2.38 mm(3) for the flowable composite and 3.43 ± 2.50 mm(3) for the conventional composite.

Conclusions: The flowable and conventional composites used in this study have similar clinical efficacy after two years of service when placed as Class I occlusal restorations having isthmus widths less than one-half the intercuspal distance.

Download full-text PDF

Source
http://dx.doi.org/10.2341/15-038-CDOI Listing

Publication Analysis

Top Keywords

volumetric wear
16
flowable conventional
8
conventional composite
8
occlusal restorations
8
secondary caries
8
flowable
5
conventional
5
composite
5
two-year
4
two-year randomized
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!