Experimental Studies of Boronophenylalanine ((10)BPA) Biodistribution for the Individual Application of Boron Neutron Capture Therapy (BNCT) for Malignant Melanoma Treatment.

Int J Radiat Oncol Biol Phys

Department of Radiobiology, National Atomic Energy Commission, San Martín, Argentina; National Research Council of Argentina, Buenos Aires, Argentina. Electronic address:

Published: October 2015

Purpose: Patients with the same histopathologic diagnosis of cutaneous melanoma treated with identical protocols of boron neutron capture therapy (BNCT) have shown different clinical outcomes. The objective of the present studies was to evaluate the biodistribution of boronophenilalanina ((10)BPA) for the potential application of BNCT for the treatment of melanoma on an individual basis.

Methods And Materials: The boronophenilalanine (BPA) uptake was evaluated in 3 human melanoma cell lines: MEL-J, A375, and M8. NIH nude mice were implanted with 4 10(6) MEL-J cells, and biodistribution studies of BPA (350 mg/kg intraperitoneally) were performed. Static infrared imaging using a specially modified infrared camera adapted to measure the body infrared radiance of small animals was used. Proliferation marker, Ki-67, and endothelial marker, CD31, were analyzed in tumor samples.

Results: The in vitro studies demonstrated different patterns of BPA uptake for each analyzed cell line (P<.001 for MEL-J and A375 vs M8 cells). The in vivo studies showed a maximum average boron concentration of 25.9 ± 2.6 μg/g in tumor, with individual values ranging between 11.7 and 52.0 μg/g of (10)B 2 hours after the injection of BPA. Tumor temperature always decreased as the tumors increased in size, with values ranging between 37 °C and 23 °C. A significant correlation between tumor temperature and tumor-to-blood boron concentration ratio was found (R(2) = 0.7, rational function fit). The immunohistochemical studies revealed, in tumors with extensive areas of viability, a high number of positive cells for Ki-67, blood vessels of large diameter evidenced by the marker CD31, and a direct logistic correlation between proliferative status and boron concentration difference between tumor and blood (R(2) = 0.81, logistic function fit).

Conclusion: We propose that these methods could be suitable for designing new screening protocols applied before melanoma BNCT treatment for each individual patient and lesion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2015.05.039DOI Listing

Publication Analysis

Top Keywords

boron neutron
8
neutron capture
8
capture therapy
8
therapy bnct
8
bpa uptake
8
experimental studies
4
studies boronophenylalanine
4
boronophenylalanine 10bpa
4
10bpa biodistribution
4
biodistribution individual
4

Similar Publications

Current research trends and hotspots of boron neutron capture therapy: a bibliometric and visualization analysis.

Front Oncol

December 2024

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.

Purpose: This study aimed to describe the trends, current hotspots, and future directions in boron neutron capture therapy (BNCT) through a bibliometric analysis.

Methods: Articles related to BNCT published before 2023-12-31 were retrieved from the Web of Science Core Collection database. VOSviewer, R, and CiteSpace were used for bibliometric analysis and visualization.

View Article and Find Full Text PDF

This study presents a compact accelerator-driven neutron source design with a thermal neutron port and an epithermal neutron port for Boron Neutron Capture Therapy (BNCT), based on 10 mA 2.5 MeV protons bombarding on a 100 μm thick disc-shaped Li target with a diameter of 10 cm. The moderator consists of 2 parts, the epithermal neutron moderator and the thermal neutron moderator.

View Article and Find Full Text PDF

Fractionated alpha and mixed beam radiation promote stronger pro-inflammatory effects compared to acute exposure and trigger phagocytosis.

Front Cell Neurosci

December 2024

Department of Molecular Biosciences, Centre for Radiation Protection Research, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.

Introduction And Methods: Aiming to evaluate safety aspects of a recently proposed approach to target Alzheimer's disease, we mimicked a complex boron neutron capture therapy field using a mixed beam consisting of high- and low-linear energy transfer (LET) radiation, Am alpha particles (α) and/or X-ray radiation respectively, in human microglial (HMC3) cells.

Results: Acute exposure to 2 Gy X-rays induced the strongest response in the formation of γH2AX foci 30 min post irradiation, while α- and mixed beam-induced damage (α:X-ray = 3:1) sustained longer. Fractionation of the same total dose (0.

View Article and Find Full Text PDF

Development of anticoincidence detector specializing in small-angle Compton scattering gamma rays for boron neutron capture therapy.

Appl Radiat Isot

December 2024

Division of Quantum and Radiation Engineering, Graduate School of Engineering, Osaka Metropolitan University, 1-2 Gakuen-cho, Naka-ku, Sakai, Osaka, 599-8570, Japan.

A novel anticoincidence detector is proposed for the measurement of 478 keV gamma radiation for evaluation of boron neutron capture therapy. The Compton continuum around the target photopeak position is effectively suppressed by measuring only the Compton gamma rays scattered at small angles from the primary detector. A numerical evaluation using Monte Carlo simulations estimated an 80% reduction in counts, and the developed prototype detector showed 4% suppression of the Compton continuum of cobalt-60 gamma rays.

View Article and Find Full Text PDF

In this study, the gamma radiation shielding properties of concrete samples reinforced with 10%, 20%, 30%, 40% and 50% of the cement weight of brass alloy were investigated. To test gamma shielding performance of the samples, mass and linear attenuation coefficients, half and tenth value layers, effective atomic number and radiation protection efficiency parameters were determined experimentally, theoretically and Monte Carlo simulations (GEANT4 and FLUKA). The studies were performed at 11 different gamma energies that range from 59.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!