Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: The purpose of this study was to describe the operative procedures and clinical outcomes of a new three-column internal fixation system with anatomical locking plates on the tibial plateau to treat complex three-column fractures of the tibial plateau.
Methods: From June 2011 to May 2015, 14 patients with complex three-column fractures of the tibial plateau were treated with reduction and internal fixation through an anterolateral approach combined with a posteromedial approach. The patients were randomly divided into two groups: a control group which included seven cases using common locking plates, and an experimental group which included seven cases with a new three-column internal fixation system with anatomical locking plates.
Results: The mean operation time of the control group was 280.7 ± 53.7 minutes, which was 215.0 ± 49.1 minutes in the experimental group. The mean intra-operative blood loss of the control group was 692.8 ± 183.5 ml, which was 471.4 ± 138.0 ml in the experimental group. The difference was statistically significant between the two groups above. The differences were not statistically significant between the following mean numbers of the two groups: Rasmussen score immediately after operation; active extension-flexion degrees of knee joint at three and 12 months post-operatively; tibial plateau varus angle (TPA) and posterior slope angle (PA) immediately after operation, at three and at 12 months post-operatively; HSS (The Hospital for Special Surgery) knee-rating score at 12 months post-operatively. All fractures healed.
Conclusion: A three-column internal fixation system with anatomical locking plates on tibial plateau is an effective and safe tool to treat complex three-column fractures of the tibial plateau and it is more convenient than the common plate.