Background: Despite thorough analyses of the analytical performance of Clostridium difficile tests and test algorithms, the financial impact at hospital level has not been well described. Such a model should take institution-specific variables into account, such as incidence, request behaviour and infection control policies.
Aim: To calculate the total hospital costs of different test algorithms, accounting for days on which infected patients with toxigenic strains were not isolated and therefore posed an infectious risk for new/secondary nosocomial infections.
Methods: A mathematical algorithm was developed to gather the above parameters using data from seven Flemish hospital laboratories (Bilulu Microbiology Study Group) (number of tests, local prevalence and hospital hygiene measures). Measures of sensitivity and specificity for the evaluated tests were taken from the literature. List prices and costs of assays were provided by the manufacturer or the institutions. The calculated cost included reagent costs, personnel costs and the financial burden following due and undue isolations and antibiotic therapies. Five different test algorithms were compared.
Findings And Conclusion: A dynamic calculation model was constructed to evaluate the cost:benefit ratio of each algorithm for a set of institution- and time-dependent inputted variables (prevalence, cost fluctuations and test performances), making it possible to choose the most advantageous algorithm for its setting. A two-step test algorithm with concomitant glutamate dehydrogenase and toxin testing, followed by a rapid molecular assay was found to be the most cost-effective algorithm. This enabled resolution of almost all cases on the day of arrival, minimizing the number of unnecessary or missing isolations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhin.2015.06.001 | DOI Listing |
Neurosurg Rev
January 2025
Department of Neurosurgery, Mount Sinai Hospital, Icahn School of Medicine, New York City, NY, USA.
Currently, the World Health Organization (WHO) grade of meningiomas is determined based on the biopsy results. Therefore, accurate non-invasive preoperative grading could significantly improve treatment planning and patient outcomes. Considering recent advances in machine learning (ML) and deep learning (DL), this meta-analysis aimed to evaluate the performance of these models in predicting the WHO meningioma grade using imaging data.
View Article and Find Full Text PDFSci Rep
January 2025
Amity Institute of Environmental Sciences (AIES), Amity University Uttar Pradesh (AUUP), Sector-125, Gautam Budh Nagar, Noida, 201313, India.
This study focused on simulating the adsorption-based separation of Methylene Blue (MB) dye utilising Oryza sativa straw biomass (OSSB). Three distinct modelling approaches were employed: artificial neural networks (ANN), adaptive neuro-fuzzy inference systems (ANFIS), and response surface methodology (RSM). To evaluate the adsorbent's potential, assessments were conducted using Fourier-transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM).
View Article and Find Full Text PDFSci Rep
January 2025
National Clinical Research Center for Geriatrics, West China Hospital of Sichuan University, Chengdu, Sichuan Province, China.
This study aimed to develop a real-time, noninvasive hyperkalemia monitoring system for dialysis patients with chronic kidney disease. Hyperkalemia, common in dialysis patients, can lead to life-threatening arrhythmias or sudden death if untreated. Therefore, real-time monitoring of hyperkalemia in this population is crucial.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical Engineering, College of Engineering, Taif University, Taif, 21944, Saudi Arabia.
This paper presents a novel approach to modeling and controlling a solar photovoltaic conversion system(SPCS) that operates under real-time weather conditions. The primary contribution is the introduction of an uncertain model, which has not been published before, simulating the SPCS's actual functioning. The proposed robust control strategy involves two stages: first, modifying the standard Perturb and Observe (P&O) algorithm to generate an optimal reference voltage using real-time measurements of temperature, solar irradiance, and wind speed.
View Article and Find Full Text PDFSci Rep
January 2025
Institute of Biological and Chemical Systems - Functional Molecular Systems (IBCS-FMS), Karlsruhe Institute of Technology (KIT), Karlsruhe, 76344, Germany.
Multiple linear regression models were trained to predict the degree of substitution (DS) of cellulose acetate based on raw infrared (IR) spectroscopic data. A repeated k-fold cross validation ensured unbiased assessment of model accuracy. Using the DS obtained from H NMR data as reference, the machine learning model achieved a mean absolute error (MAE) of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!