Incidence, severity, and impact of hyperhidrosis in people with lower-limb amputation.

J Rehabil Res Dev

Division of Physical Medicine and Rehabilitation, University of Utah School of Medicine, Salt Lake City, UT;

Published: April 2016

To assess the incidence and severity of self-reported hyperhidrosis in patients with amputation and understand its effects on prosthetic fit or function, a cross-sectional survey of patients at two amputee clinics was performed. Responses from 121 subjects with lower-limb amputation were analyzed. Of these subjects, 66% reported sweating to a degree that it interfered with daily activities, as measured by the Hyperhidrosis Disease Severity Scale. There was a significant association between sweating and interference with prosthetic fit and function. Sweating was more severe in cases of transtibial amputations, patients under the age of 60, warm weather, and vigorous activity. There was no relationship between severity of sweating and time since amputation, etiology of amputation, duration of daily prosthetic use, or reported ability to perform functional tasks. Subjects reported trying multiple interventions, but the self-reported effectiveness of these treatments was low. Hyperhidrosis, a common problem associated with prosthetic usage, varies in severity and often interferes with daily activities. Sweating severity is associated with poor prosthetic fit and function. Risk factors include younger age and transtibial amputation status. Treatment strategies generally lack efficacy. The results of this study may provide guidance for future interventions and treatment options.

Download full-text PDF

Source
http://dx.doi.org/10.1682/JRRD.2014.04.0108DOI Listing

Publication Analysis

Top Keywords

prosthetic fit
12
fit function
12
incidence severity
8
lower-limb amputation
8
daily activities
8
amputation
6
severity
5
prosthetic
5
sweating
5
severity impact
4

Similar Publications

Acquired Ankyloblepharon Correction Using Ocular Surface and Tarsal Mucous Membrane Grafting in Cicatrizing Ocular Surface Diseases.

Ophthalmic Plast Reconstr Surg

October 2024

Hariram Motumal Nasta & Renu Hariram Nasta Ophthalmic Plastic Surgery Services.

Purpose: To report the long-term surgical outcomes of acquired ankyloblepharon correction using mucous membrane graft.

Methods: Five eyes of 4 patients (median age, 19 years) with acquired ankyloblepharon were managed using eyelid splitting and mucous membrane graft anchored to the recti muscles on the bulbar surface in the respective quadrant and onto the bare tarsal surface. Outcome measures include a change in the palpebral fissure width, ability to fit scleral contact lenses, visual acuity, and cosmesis.

View Article and Find Full Text PDF

Full-mouth rehabilitation of a patient with implant-supported fixed dental prostheses using CAD-CAM frameworks.

Prim Dent J

December 2024

Ilser Turkyilmaz DMD, PhD Associate Dean of Digital Innovation, Professor and Chair, Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, Ohio, USA.

Conventional complete denture wearers often complain of lack of stability and overall discomfort with their prostheses. The advent of dental implants and advanced prosthetic methods have greatly improved this struggle for edentulous patients. The utilisation of computer-aided design and computer-aided manufacturing (CAD-CAM) technology has only further enhanced the capabilities of dental practitioners to rapidly and accurately restore edentulism.

View Article and Find Full Text PDF

Design of semi-open prosthetic socket with constant force for lower limb.

Prosthet Orthot Int

December 2024

School of Intelligent Rehabilitation Engineering, Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.

Background: Prosthetic socket is a key component of the prosthesis for clinical application; its performance directly affects the adaptation of the residual limb to the prosthetic socket. There are long-term and short-term volume fluctuation of the residual limb. The volume fluctuation of the residual limb will lead to the pressure mismatch at the interface of the residual limb and the prosthetic socket, which will cause a series of skin and fit problems.

View Article and Find Full Text PDF

Background: Iterative design and modification are used to manufacture lower limb prosthetic sockets that meet users' needs while also fulfilling safety and mobility criteria. Greater understanding of the expectations of prosthesis users regarding prosthetic fit as well as their experiences at the time of socket fitting is needed.

Objectives: Describe lower limb prosthesis user perceptions and experiences of socket comfort and discomfort during their last fitting and compare this to their expectations for a perfectly fitting socket and their satisfaction with the socket they had fitted.

View Article and Find Full Text PDF

Background: Modern techniques in lower extremity amputation have made significant advances to improve prosthetic control and soft-tissue envelopes through various techniques, including medial thighplasties. These advances are necessary to enhance the fit and functionality of the prosthesis in transfemoral amputations.

Methods: We performed a retrospective review of all thighplasties performed at our institution in patients with ipsilateral transfemoral amputation from November 2017 to December 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!