Objectives: the purpose of this study was to compare the postoperative radiological and clinical outcomes with minimally invasive percutaneous osteosynthesis using three implants: volar locking plate, intramedullary nail system and nonbridging external fixator for distal radius fractures.
Methods: forty-eight patients (A group, 16; B group 16; C group 16) underwent minimally invasive percutaneous osteosynthesis of reductible and unstable displaced (Type IIB by Rayhack Classification) distal radius fractures. In B group intramedullary nail system was used, in A group the patients were treated with volar locking plate and in C group the patients were treated by nonbridging external fixator from January 2011 to December 2012. The mean follow-up period was 12 months. Radiologic parameters, range of motion, grip strength, and disability of the arm, shoulder, and hand score were evaluated at each examination (3rd and 6th week, and 12th months). The visual analog scale of wrist pain and complications were assessed at the final follow-up.
Results: the groups did not differ significantly in radiological outcomes after 12 months, but the clinical results, VAS scale and dash score in group A (volar locking plate) and B (nail intramedullary) were statistically significantly better than that of C group (nonbridging external fixator). One patient underwent an osteosynthesis with nail intramedullary and another with external fixator (C group) developed persistent pain near the site of the superficial radial nerve because of the distal's screw and pins, respectively.
Conclusion: in clinical parameters, significant differences in outcomes were found between groups A and B after six weeks versus C group.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4511660 | PMC |
http://dx.doi.org/10.1016/j.rboe.2014.04.003 | DOI Listing |
Am J Vet Res
January 2025
Objective: This study aimed to evaluate the clinical and radiologic findings in the treatment of live oligotrophic and pseudoarthrosis nonunions in cats using a linear external fixator.
Methods: The study included 10 cats of various breeds, ages, and sexes that had previously undergone osteosynthesis at another clinic but did not achieve successful results. These cats were diagnosed with nonunion based on clinical and radiographic examinations conducted at the Clinic of the Surgery Department, Siirt University Animal Health Practice and Research Hospital between 2022 and 2023.
J Am Podiatr Med Assoc
January 2025
†Jesse Brown VA Medical Center,820 S Damen Ave, Chicago, IL.
Total contact casting is the gold standard for plantar foot ulcers but has been questioned in heel pressure ulcers. Current offloading of heel ulcers is typically removable offloading boots. We describe using a modified posterior splint to offload heel ulcers in nonweightbearing patients.
View Article and Find Full Text PDFAME Case Rep
November 2024
Department of Orthopaedic Surgery, Sugita Genpaku Memorial Obama Municipal Hospital, Fukui, Japan.
Background: Open pelvic fractures are rare but represent a serious clinical problem with high mortality rates. Acute mortality is often associated with hemorrhage, whereas delayed mortality is most often associated with sepsis and multiple organ failure. We report a case of Wang's classification of type II open pelvic ring fracture with hemorrhagic shock and septic shock from gas gangrene.
View Article and Find Full Text PDFInjury
January 2025
Department of Orthopaedic Surgery and Rehabilitation, University of Florida-Jacksonville, Jacksonville, FL USA. Electronic address:
Introduction: External fixators are utilized to temporarily stabilize bicondylar tibial plateau fractures. They can be prepped during definitive surgery to help maintain fracture length and alignment. However, there is a potential for increased infection by leaving the external fixator on during the surgery.
View Article and Find Full Text PDFInjury
January 2025
Department of Surgery, The Trauma and Orthopaedic Research Unit, The Canberra Hospital, Garran, Australian Capital Territory, Australia.
Background: Unstable posterior pelvic-ring fractures are rare and difficult to manage. There are many injury patterns, they are associated with high morbidity and mortality, and optimal surgical management remains contentions. This study aims to compare outcomes and complications for different surgical management of these injuries.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!